![ACR STOVES Neo 1C-ECO Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/acr-stoves/neo-1c-eco/neo-1c-eco_technical-manual_2841014014.webp)
14
Installation of the unit
The appliance is supplied pre-assembled
with the flue spigot in the top exit position
and the Smoke Exempt stop in place.
The Smoke Exempt stop must not be removed
unless the appliance is installed in a non-
smoke exempt area and this action should only
be undertaken by a competent person.
To remove the smoke exempt stop,
remove the M8 smoke exempt bolt from
the underside of the combustion chamber,
this will allow the air control wheel to fully
close.
Pre-installation assembly
Carefully remove the wooden packing
crate and plastic weather shield from
the stove, open the appliance and
check the contents.
Make sure that none of the internal
components have moved in transit.
If you intend to use the appliance as a
rear flue stove please follow the below
instructions.
Remove the vermiculite baffle by lifting
and easing the rear edge forward
through the combustion chamber.
Remove the upper steel baffle.
Remove the partially cut rear blanking
plate from the outer rear panel and
discard Remove the 2 x 10mm bolts
located on the inner rear blanking plate
and remove.
Remove the free floating top plate and
remove the 2 x 10mm bolts securing
the flue collar in place.
Reattach the flue collar to the rear exit
aperture and attach the inner blanking
plate to the top flue aperture.
Replace the free floating top plate and
insert the cosmetic flat steel plate into
the recess on the top plate.
The flue system can now be installed
from the rear flue collar inline with
Building Regulations document J.
Stove installation
Prior to installation please confirm that the
correct model ACR stove has been
supplied.
Packing list
Your Neo-Eco stove will contain:
• 1 x Technical manual
• 1 x Pair of ACR heat resistant gloves
• 1 x Ashpan lid
• 1 x Energy label
• 1 x Cosmetic blanking plate
If in the unusual instance that any of these
component are missing please contact
either your suppling dealer or ACR direct
to inform as failure to do this may result in
these items incurring a charge.
Installation requirements
The installation must comply with Building
Regulations document J, European
Standards and Local authority bylaws.
Commissioning and handover
After the installation is complete test as
per Building Regulations document J and
complete the commissioning document
located in this manual.
Failure to complete the commissioning
document contained within this manual
may invalidate the warranty
Advise the customer to “burn in” the stove
and not to fire the appliance at full output
for at 3 - 4 days.
Explain that the stove can provide a much
higher or lower output than the rated heat
outputs depending upon fuel loads used
and how they are operated.
Warn the customer that using excessive
air (having the air controls fully open for
too long) can over-fire and irreparably
damage the stove.
Damage caused by over firing is NOT
covered by any warranty.
On completion of the installation and
commissioning, check all parts of the
appliance are correctly fitted and ensure
that the operating instructions and
operating tools (including gloves and any
multi-functional tool if supplied) for the
stove are left with the customer.
You must be sure to advise the customer
on the correct use of the appliance with
the fuels likely to be used on the stove and
warn them to use only the recommended
fuels for the stove.
1
2
3
4
5
6
7
8
9
10
NEO ECO range manual 0620-6 25/06/2020 11:18 Page 14