RCL-600
TROUBLE SHOOTING
①
If 24V DC is measured:
②
No 24V DC output?
RCL-600 TROUBLE SHOOTING
Lamp does not turn on
Replace the lamp according to the instructions
Remove the power head according to the directions on page
7
. Turn on the
power by pushing the power button on the remote control panel. Check on
the 1
st
and 2
nd
contacts from the left side of PCB receptacle (see picture
3
,
page
8
) whether 24V DC is present.
Does not turn on?
onononon the lamp
Check the
Ballast
, which is built into the power head, according
to directions on pages
8
and
9
.
“
How to check the ballast
”.
The
Starter
is faulty.
Replace the starter according to
directions on pages
14
and
15
.
The
Ballast
is faulty.
Replace the ballast according to
directions on pages
11, 12
and
13
.
There is a possibility of a problem inside the driver PCB.
Replace the printed circuit board PP-207A according to directions on page
10
.
“How to check the print circuit board PP-207A”.
There is a possibility that the brush holder faulty.
Replace the brush holder according to directions on pages
16, 17
and
18
.
The printed circuit board PP-207A is faulty.
Replace the printed circuit board PP-207A according to directions on page
21
and
22
.
Normal
Abnormal
Normal
Abnormal