![ACR Electronics RCL-600 SEARCHLIGHT Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/acr-electronics/rcl-600-searchlight/rcl-600-searchlight_trouble-shooting-and-parts-replacement-manual_2840850011.webp)
11
4. Method to replace the ballast
4-1 Use the following tools
・
Phillips screw driver
・
Pliers
・
7mm flat spanner
・
6mm Hexagonal wrench
・
Silicon compound
・
Ballast (PXE-150-DC24)
4-2 Procedure for exchanging the PCBs
1) Remove the power head according to the instruction on page
7
.
2) Remove the spring with pliers as indicated by the arrow in picture
8
.
Picture
8
3) Remove cables connected to the starter. See picture 9.
Note: Remove cables
after marking them
in order to replace them in their proper order.
Picture
9