background image

Y1-03-0141D

 

18

 

APPENDIX E - WARRANTY, USEFUL LIFE POLICY, 
NOTICES 

Limited Warranty 

This product is warranted against factory defects in material and workmanship for a 
period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty 
period ACR Electronics, Inc. will repair or, at its option, replace the unit

 

at no cost to 

you  for  labor, materials  and  return  transportation  from  ACR.  For  further assistance, 
please  contact  our  Technical  Service  Department  at  ACR  Electronics,  Inc.,  5757 
Ravenswood 

Road, 

Fort 

Lauderdale, 

FL 

33312-6645. 

Email: 

[email protected]

,  Fax:  +1  (954)  983-5087,  Telephone:  +1  (954)  981-

3333. 

 

This  warranty  does  not  apply  if  the  product  has  been  damaged  by  accident  or 
misuse,  or  as  a  result  of  service  or  modification  performed  by  an  unauthorized 
factory.  Except  as  otherwise  expressly  stated  in  the  previous  paragraph,  THE 
COMPANY  MAKES  NO  REPRESENTATION  OR  WARRANTY  OF  ANY  KIND, 
EXPRESS  OR  IMPLIED,  AS  TO  MERCHANTABILITY,  FITNESS  FOR  A 
PARTICULAR  PURPOSE,  OR  ANY  OTHER  MATTER  WITH  RESPECT  TO  THIS 
PRODUCT.  The  Company  shall  not  be  liable  for  consequential  or  special 
damages.To  place  the  warranty  in  effect,  register  online  at 

www.acrelectronics.com

 

or return the attached card within 10 days. 

 

*Five years for the following products: EPIRB, PLB, S-VDR, SSAS. 
 

Useful Life Policy 

The  typical  service  life  of  a  properly  maintained  Product  is  limited  to  12  years  from 
date of manufacture. Products that are 12 years and 1 month or older from date of 
manufacture  will  not  be  serviced  by  ACR  or  our  Battery  Replacement  Centers.  A 
Product that is 12 or less years old from date of manufacture will be serviced as long 
as  the  unit  appears  fit  to  be  placed  back  into  its  final  operational  cycle.  Service 
includes  the  replacement  of  those  items  that  must  be  replaced  at  service  intervals 
and the verification that the device appears to be in good mechanical and electrical 
working condition by an ACR authorized service technician. 
 

Notices

 

ACR  Electronics  diligently  works  to  provide  a  high  quality  Product  Support  Manual, 
however,  despite  best  efforts,  information  is  subject  to  change  without  notice,  and 
omissions  and  inaccuracies  are  possible.  ACR  cannot  accept  liability  for  manual 
contents.  To  ensure  that  you  have  the  most  recent  version  of  the  Product  Support 
Manual, please visit the ACR website at 

www.acrelectronics.com

 

©2009  by  ACR  Electronics,  Inc.,  part  of  Cobham  plc.  All  rights  reserved. 
Reproduction  in  whole  or  in  part  is  permitted  only  with  permission  of  ACR 
Electronics, Inc. Ongoing product improvements may change product specifications 
without notice. 

 

Trademarks or registered trademarks are the property of their respective owners. 
 

 

Содержание RCL-50

Страница 1: ......

Страница 2: ... 1 954 981 3333 or email service acrelectronics com Please be ready to provide the technician with the page number you wish to discuss If you have a question that is not covered in the manual please visit our website and access the Frequently Asked Questions FAQs section for further information or call our Technical Service Department The website address is www acrelectronics com If in the future ...

Страница 3: ...SECTION 4 REMOTE CONTROL SYSTEM_________________________ 5 SECTION 5 URP 102 POINT PAD _____________________________ 5 SECTION 6 URC 102 Master Controller _________________________ 9 APPENDIX B BULB REPLACEMENT PROCEDURE _________________ 14 APPENDIX C PRODUCT COMPONENTS ________________________ 15 APPENDIX E WARRANTY USEFUL LIFE POLICY NOTICES _________ 18 PLEASE READ ALL WARNINGS CAUTIONS AND NO...

Страница 4: ...quality raw materials and quality controlled manufacturing produce a superior product The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man This assures that the products we produce can stand up to the tough marine environment With proper care and maintenance your searchlight will be in service for years to come ACR is proud to be ISO 9001 certified the ...

Страница 5: ...s it attractive for recreational and commercial vessels The searchlight is totally enclosed and is made of rugged aluminum alloy It is gasketed and finished to be resistant to the weather Mounting Make sure the area is clean and dry The searchlight can be mounted where desired using appropriate length 3 16 diameter stainless steel fasteners four 4 nylon shoulder washers are supplied with the RCL 5...

Страница 6: ...tion Generally the Point Pad should be mounted in a protected area Install the surface mount Point Pad by drilling three 3 holes in the dashboard location using the Point Pad surface mount template supplied Mount the Point Pad to the dashboard using the gasket washers and nuts supplied Use a sealant around the bolt holes to protect from moisture intrusion When the flush mount option is selected cu...

Страница 7: ...th all RCL 100 50 searchlights and with the URC 101 Master Controller CAUTION The URP 102 Point Pad is not recommended for use with the first generation URC 100 Master Controllers Figure 2 Point Pad Connection Block Diagram URP 102 Point Pad URP 102 Point Pad URP 102 Point Pad URC 102 Master Controller Unit URC 102 Master Controller Unit Power Source Power Source RG 59 Coaxial Cable RG 59 Coaxial ...

Страница 8: ...Arrows to raise or lower the Searchlight beam To activate the XRCiZ feature press and hold the ON OFF button for greater than 5 seconds The green LED indicates XRCiZ feature is enabled To deactivate the XRCiZ feature Press and hold the ON OFF button for greater than 5 seconds The red LED indicates XRCiZ feature is disabled An LED blinking red green indicates that the XRCiZ feature is now exercisin...

Страница 9: ...Y1 03 0141D 8 Figure 4 URP 102 Point Pad Surface Mount Case Figure 5 URP 102 Point Pad Flush Mount Case ...

Страница 10: ...our mounting location Use a sealant in fastener holes to prevent moisture intrusion General wiring scheme The RCL 50B has a unique wiring scheme Special attention must be paid to the following chart The Master Controller is supplied with an in line fuse holder on the orange power lead Use only 15 amp fuses in this fuse holder See Figure 9 for the master controller wiring diagram WARNING Failure to...

Страница 11: ...e coax has been routed strip the insulation and crimp the F connectors in place Screw the F connectors to the master controller and the Point Pad Wiring to Power Supply The power source must be a fused 12 VDC 5 amp supply or 24 VDC 3 amp supply Following the wiring scheme in Table 1 use the supplied butt connectors to connect the Master Controller to the power source Refer to Table 2 for proper wi...

Страница 12: ...Point Pad button will stop the current cycle and leave the searchlight to follow any additional commands To deactivate the XRCiZ feature press and hold the Point Pad on off button for greater than 5 seconds The red LED on the URC 102 Point Pad indicates that the XRCiZ feature is disabled NOTE LED feedback is not available when using RCL 100 or URC 101 Point Pads NOTE The searchlight should not be ...

Страница 13: ...Point Pads 75 ohm TV Coaxial Cable 75 ohm TV Coaxial Cable T Connector or Optional 75 Ohm Splitter for Multiple RCL 100 Point Pads Ground Blue Orange Note Wiring must be in accordance with this diagram Improper wiring will damage components 12 VDC or 24 VDC Master Controller in line 15 amp fuse Power Source Fuse Figure 7 URC 102 Master Controller Wiring Diagram ...

Страница 14: ...Y1 03 0141D 13 Figure 8 URC 102 Master Controller ...

Страница 15: ...ACR dealer or through ACR Electronics The part numbers are P N 6002 for 12V units and P N 6010 for 24V units CAUTION Failure to follow replacement instructions carefully can result in damage to bulb and or light All part sales are final To replace the lamps 1 Disconnect unit from power source and allow bulb to cool 2 Remove three screws holding the front flange and glass in place 3 To remove the o...

Страница 16: ... 0776 Washers 2 A1 05 0777 Warranty Card 1 A1 20 1019 Product Support Manual 1 Y1 03 0141 Mounting Templates 1 Y1 03 0138 1 Product No 1940 3 RCL 50B 24 V Searchlight Installation Kit includes Description Quantity ACR Part Number Searchlight RCL 50B 24 V 1 A3 06 0092 4 Kit Nylon Washers 4 1 A3 06 1940 Connector F 2 A1 03 0220 Cable Coaxial 15ft A2 07 0002 6 Master Controller URC 102 1 A3 06 2231 C...

Страница 17: ...R Part Number Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A1 25 0140 2 U Clamp 2 A1 17 1366 Nuts Nylon lock 2 A1 05 0776 Washers 2 A1 05 0777 Adapter Plate Flush mount 1 A1 18 1871 Adapter Plate Surface mount 1 A1 18 1892 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Pro...

Страница 18: ... 4 A1 03 0220 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Product No 9283 3 Remote Control Installation Kit Includes Description Quantity ACR Part Number Master Controller URC 102 1 A3 06 2231 Connector In Line 8 A1 03 0222 Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A...

Страница 19: ...ars for the following products EPIRB PLB S VDR SSAS Useful Life Policy The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers A Product that is 12 or less years old from date of manufacture will be serviced as lon...

Страница 20: ...ns EN 60945 2002 Immunity IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 6 1996 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Interrupts Manufacturer ACR Electronics Inc European ACR Electronics Inc 5757 Ravenswood Road Representative European Office Fort Lauderdale FL 33312 1 Rose Cottages Pitmore Lane USA Sway Lymington H...