The URC-102 Master Controller has the unique XRCi
Z™ feature. The XRCiZ™ feature
routinely operates all moving parts in the searchlight to keep the motors and drive
mechanism freely running. Once activated, and every 30 days thereafter, the XRCi
Z™
feature wakes up and operates the searchlight. The searchlight will rotate 360 in both
directions and the parabolic reflectors will move to the full up and down positions. This
feature keeps the searchlight in peak working order when not in service for long periods
of time.
To activate the XRCi
Z™ feature, press and hold the Point Pad™ on/off button for
greater than 5 seconds. The green LED on the URC-102 Point P
ad™ indicates that the
XRCi
Z™ feature is enabled. While enabled, the XRCiZ™ feature can be started outside
of its 30-day cycle by pressing and holding the speed button on the Point P
ad™ for
greater than 5 seconds.
While the XRCi
Z™ feature is operating the searchlight, pressing any Point Pad™ button
will stop the current cycle and leave the searchlight to follow any additional commands.
To deactivate the XRCi
Z™ feature, press and hold the Point Pad™ on/off button for
greater than 5 seconds. The red LED on the URC-102 Point P
ad™ indicates that the
XRCi
Z™ feature is disabled.
NOTE:
LED feedback is not available when using RCL-100 or URC-101 Point P
ads™.
NOTE
: The searchlight should not be covered while the XRCi
Z™ feature is enabled.
The URC-102 Master Controller provides optimum voltage to ensure the brightest
searchlight performance and long bulb life. Also to extend lamp life, the Master
Controller has a timed lamp power up feature. The searchlight lamp reaches full
intensity within 2 seconds.
The URC-102 Master Controller has a searchlight motor timeout feature. If a Point
P
ad™ rotation switch (right or left) is continuously engaged for more than 50 seconds,
the Master Controller will interrupt the operation until the Point P
ad™ switch is
disengaged. This feature will save the searchlight motor from burnout due to accidental
activation. The elevation motor has similar features which will timeout in approximately
20 seconds.