background image

 

Page | 13 
 

 

Light flickers 
on and off as 
it rotates. 

Remove  four  screws  from  the  protection  cover  (underside  of  head).  Lift  the  head 
from  the  base  and  check  the  slip  ring  and  brush  assembly  for  corrosion.  If 
corrosion  is  evident,  clean  with  a  wire  brush.  If  either  the  brush  or  slip  ring 
assembly is corroded or pitted beyond repair, they will need to be replaced. 

 

Power to 
MCU, but no 
light on RCP 
and no 
functions of 
light. 

Check the coaxial cable with an ohm meter by placing the probes on each end of 
the center conductor on the coaxial cable. If there is no meter movement, replace 
or repair the coaxial cable. If it registers a full meter reading, then the coax cable is 
ok and it is recommended that the point  pad and  MCU be sent in for testing and 
possible replacement.  

 

Extending the 
coaxial cable  

Please be sure to use 

RG 59

 coaxial cable, if there is a need to extend the coax 

between  the  Point  pad  and  the  Master  Controller  or  if  the  existing  cable  is 
damaged and needs to be replaced. 

 

Maximum 
cable length 
between the 
Master 
controller and 
the RCL 100 
light. 

WIRE SIZE 

12V SYSTEM 

24V SYSTEM 

 

 

 

# 8 AWG 

25 FEET 

100 FEET 

#10 AWG 

15 FEET 

60 FEET 

# 12 AWG 

10 FEET 

40 FEET 

 

Need to send 
the light to 
ACR for 
repair? 

Please send the light to: 
 

Technical Service, 
ACR Electronics Inc. 
5757 Ravenswood road 
Fort Lauderdale, Fl 
33312 

 

Please  add  a  memo  with  the  sender/company  name,  full  return 
address and contact number of a person that can 

OK

 a quote on 

the service/repair of the above. 

  

Содержание RCL 100

Страница 1: ...Page 1 RCL 100 Troubleshooting Breakdown List ...

Страница 2: ...ded 3 Wiring guide 3 Pointpad Master controller compatibility 5 12V 24V 5 Searchlight and Wiring Diagram 6 Breakdown procedure 7 8 Slip ring and Planet gear assembly 9 Rotation motor assembly 10 Troubleshooting the light 12 14 Parts List 15 ...

Страница 3: ... Rags 2 Phillips Screwdriver Length of wires 2 with crocodile clips on each end to connect to battery 12V Battery or Power Supply 3 5Amp capability Wiring Guide YELLOW Lamp power GREEN Lamp power RED Elevation motor WHITE Elevation motor BLACK Rotation motor BROWN Rotation motor ...

Страница 4: ...t Black Spot Right Other RCL 100 Point Pads 75 ohm TV Coaxial Cable 75 ohm TV Coaxial Cable T Connector or Optional 75 Ohm Splitter for Multiple RCL 100 Point Pads Ground Blue Orange Note Wiring must be in accordance with this diagram Improper wiring will damage components 12 VDC or 24 VDC Master Controller in line 15 amp fuse Power Source Fuse ...

Страница 5: ...r and will function properly if the individual modules are in working condition URP 100 URC 100 101 yes URP 101 URC 100 101 yes URP 102 URC 101 yes URC 102 URP 101 yes URP 100 URC 102 no URP 102 URC 100 no 12V 24V Lights The difference between a 12V light and a 24V light is ONLY the rating of the bulb If one wants to convert the light from one voltage to another the bulbs need to be replaced 12V P...

Страница 6: ...Page 6 ...

Страница 7: ...collar and carefully lift the head off the base To remove the complete Front Frame assembly from the head of the light remove the front frame and glass assembly Loosen the two lock nuts from the hex studs and turn out the two studs sufficiently to slide the assembly out ...

Страница 8: ...Page 8 Pull the Front Frame assembly out of the searchlight Complete Reflector elevation motor assembly ...

Страница 9: ...ntacts mounted in the head of the light RED WHITE UP AND DOWN GREEN YELLOW RIGHT AND LEFT View of the two plastic gears driven by the Rotation motor and the contact assembly that transfer the voltage from the slip ring to the bulbs and elevation motor 3 RED 1 WHITE 2 GREEN 4 YELLOW Planet Gear Contact assembly ...

Страница 10: ...Page 10 Rotation motor It is actually an assembly that consists of a motor and a gearbox with spindle gear GEARBOX MOTOR ...

Страница 11: ...hm meter as you would a normal incandescent house bulb Remove without touching the bulb with your hand the bulb from the socket and connect the leads to a 6V battery to test them If the bulbs test good check for corrosion on the brush assembly mounted at the bottom of the housing or on the slip ring assembly mounted in the base If there is corrosion on either the brush or slip ring assemblies gent...

Страница 12: ...ght If you change the POLARITY it should move the other way If this happens without a problem the MCU Master control unit is faulty and needs to be replaced If not do the following Remove the four screws underneath the head of the light to loosen the protection cover Gently lift the head from the base in order to view the two plastic gears by turning the head upside down to see them If they are in...

Страница 13: ...r reading then the coax cable is ok and it is recommended that the point pad and MCU be sent in for testing and possible replacement Extending the coaxial cable Please be sure to use RG 59 coaxial cable if there is a need to extend the coax between the Point pad and the Master Controller or if the existing cable is damaged and needs to be replaced Maximum cable length between the Master controller...

Страница 14: ...ight to Technical Service ACR Electronics Inc 5757 Ravenswood road Fort Lauderdale Fl 33312 Please add a memo with what needs to be done refurbishment sender company name full return address and contact number of a person that can OK a quote on the complete refurbishment of the light ...

Страница 15: ...P RING HRMK 2100 HOUSING HRMK 2101 FRONT FRAME HRMK 2102 PROTECTION COVER HRMK 2103 U TYPE BASE HRMK 2200 FRONT FRAME GASKET HRMK 2202 O RING SMALL HRMK 2203 O RING LARGE HRMK 2300 BRUSH ASSEMBLY HRMK 2500 REFLECTOR HOLDER HRMK 2501 SOCKET HOLDER HRMK 4100 FRONT FRAME ASSEMBLY HRMK 4200 ELEVATION MOTOR HRMK 4300 ROTATION MOTOR 9283 3 COMPLETE MASTER CONTROLLER POINT PAD AND COAXIAL CABLE SET 1927 ...

Отзывы: