Light flickers
on and off as
it rotates.
Remove four screws from the protection cover (underside of head). Lift the head
from the base and check the slip ring and brush assembly for corrosion. If
corrosion is evident, clean with a wire brush. If either the brush or slip ring
assembly is corroded or pitted beyond repair, they will need to be replaced.
Power to
MCU, but no
light on RCP
and no
functions of
light.
Check the coaxial cable with an ohm meter by placing the probes on each end of
the center conductor on the coaxial cable. If there is no meter movement, replace
or repair the coaxial cable. If it registers a full meter reading, then the coax cable is
ok and it is recommended that the point pad and MCU be sent in for testing and
possible replacement.
Extending the
coaxial cable
Please be sure to use
RG 59
coaxial cable, if there is a need to extend the coax
between the Point pad and the Master Controller or if the existing cable is
damaged and needs to be replaced.
Maximum
cable length
between the
Master
controller and
the RCL 100
light.
WIRE SIZE
12V SYSTEM
24V SYSTEM
# 8 AWG
25 FEET
100 FEET
#10 AWG
15 FEET
60 FEET
# 12 AWG
10 FEET
40 FEET
Need to send
the light to
ACR for
repair?
Please send the light to:
Technical Service,
ACR Electronics Inc.
5757 Ravenswood road
Fort Lauderdale, Fl
33312
Please add a memo with the sender/company name, full return
address and contact number of a person that can
OK
a quote on
the service/repair of the above.