background image

 
 
 
 
 
 
 
 
 
 
 

Содержание 3900

Страница 1: ......

Страница 2: ...ny has four divisions that collectively specialize in the provision of components subsystems and services that keep people safe improve communications and enhance the capability of aerospace and defense platforms CAUTION Before proceeding to install test or use your new ACR Electronics product please read this Product Support Manual in its entirety If you have questions regarding the contents of t...

Страница 3: ...GENERAL _______________________________3 SECTION TWO OPERATING INSTRUCTIONS_______________5 SECTION THREE TESTING AND MAINTENANCE ___________7 APPENDIX A WARRANTY USEFUL LIFE POLICY NOTICES 11 PLEASE READ ALL WARNINGS CAUTIONS AND NOTES CAREFULLY ...

Страница 4: ...rs to assist in non visual battery replacement The case is fabricated of high impact cut resistant thermoplastic material and designed to insure watertight integrity of the main body case The light utilizes a xenon strobe lamp is powered by two AA batteries and is actuated by a magnetic reed switch The light is designed for one handed operation and may be operated by either hand or attached to any...

Страница 5: ... sufficient to fire the xenon flash tube This stepped up voltage is so timed that the flash tube will fire between 40 60 flashes per minute IR filter in storage position ACR P N 4459 Flashguard ACR P N 4463 Strobe lamp Electronics compartment ON OFF magnetic slide switch Lanyard Battery alkaline AA Battery door ACR P N 9338 Blue filter in storage position not visible when stored Figure 1 Slide for...

Страница 6: ...ight With the flashguard shield in the retracted stored position slightly raise the IR filter and rotate it either left right 90 push filter in to lock into place See Figure 2 Figure 2 d IR Light With the flashguard shield in the retracted stored position insure that the IR filter is resting on the top vertical end of the light over the clear lens then push filter down to lock into place See Figur...

Страница 7: ... light to lock it into position While holding the main body case with either hand grasp the flashguard shield with the other hand and pull it up until it stops or a slight locking sound is detected then release This is an indication that the blue filter has been released and fully engaged to its proper operating position See Figure 4 Figure 4 Stored Turn On IR light Raise Shield Turn ON Blue light...

Страница 8: ...tly observe the light flashes during this evaluation This inspection should be performed in a dark room or enclosure If any light fails to meet the 50 10 flash rate requirements check the batteries and if necessary replace both batteries and repeat the test Additionally the battery contacts in the battery well should be checked and if necessary cleaned with a small brush Hold vertical while using ...

Страница 9: ...flashguard and pushing upward until it stops NOTE Standard ambient temperature for performing flash rate test is 70 Fahrenheit A lower temperature may result in somewhat lower flash rates c BA 3058 U battery AA Alkaline or equivalent Currently only a commercial test fixture exists to test the BA 3058 Radio Shack part number 910 2135 Type 22 096 or equivalent Therefore batteries surpassing their li...

Страница 10: ... 5V AA Alkaline 1 Check the battery case for cracks swelling or leakage Replace as necessary 2 CAUTION Do not mix different battery brands 3 CAUTION Do not mix old and new batteries 4 CAUTION Do not mix different battery types e g lithium and alkaine 5 Replace batteries if device is used on a mission or annually 5 Alignment No alignment procedures or special inspection requirements must be perform...

Страница 11: ... each other Then slide the new flashguard in place until it clicks into the locked position b To replace the battery door Unscrew the wire cable from the insert in the battery compartment To install new battery door screw the cable end through the insert in the battery compartment The cable is held in place after the threaded cable end goes all the way through the insert c To replace the IR filter...

Страница 12: ...RB PLB S VDR SSAS USEFUL LIFE POLICY The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers A Product that is 12 or less years old from date of manufacture will be serviced as long as the unit appears fit to be pl...

Отзывы: