background image

 

Y1-03-0146E 

11 

 

APPENDIX A 

– WARRANTY, USEFUL LIFE POLICY, 

NOTICES 

LIMITED WARRANTY 

This product is warranted against factory defects in material and workmanship for a 
period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty 
period ACR Electronics, Inc. will repair or, at its option, replace the unit

 

at no cost to 

you  for  labor,  materials  and  return  transportation  from  ACR.  For  further  assistance, 
please  contact  our  Technical  Service  Department  at  ACR  Electronics,  Inc.,5757 
Ravenswood 

Road, 

Fort 

Lauderdale, 

FL 

33312-6645. 

Email: 

[email protected]

,  Fax:  +1  (954)  983-5087,  Telephone:  +1  (954)  981-

3333. 
 
This  warranty  does  not  apply  if  the  product  has  been  damaged  by  accident  or 
misuse,  or  as  a  result  of  service  or  modification  performed  by  an  unauthorized 
factory.  Except  as  otherwise  expressly  stated  in  the  previous  paragraph,  THE 
COMPANY  MAKES  NO  REPRESENTATION  OR  WARRANTY  OF  ANY  KIND, 
EXPRESS  OR  IMPLIED,  AS  TO  MERCHANTABILITY,  FITNESS  FOR  A 
PARTICULAR  PURPOSE,  OR  ANY  OTHER  MATTER  WITH  RESPECT  TO  THIS 
PRODUCT. The Company shall not be liable for consequential or special damages. 
 
To  place  the  warranty  in  effect,  register  online  at 

www.acrelectronics.com

  or  return 

the attached card within 10 days. 
 
*Five years for the following products: EPIRB, PLB, S-VDR, SSAS. 

USEFUL LIFE POLICY 

The  typical  service  life  of  a  properly  maintained  Product  is  limited  to  12  years  from 
date  of manufacture. Products that are  12  years and  1 month  or older from date  of 
manufacture  will  not  be  serviced  by  ACR  or  our  Battery  Replacement  Centers.  A 
Product that is 12 or less years old from date of manufacture will be serviced as long 
as  the  unit  appears  fit  to  be  placed  back  into  its  final  operational  cycle.  Service 
includes  the  replacement  of  those  items  that  must  be  replaced  at  service  intervals 
and the verification that the device appears to be in good mechanical and electrical 
working condition by an ACR authorized service technician. 

 

NOTICES

 

 
ACR  Electronics  diligently  works  to  provide  a  high  quality  Product  Support  Manual, 
however,  despite  best  efforts,  information  is  subject  to  change  without  notice,  and 
omissions  and  inaccuracies  are  possible.  ACR  cannot  accept  liability  for  manual 
contents.  To  ensure  that  you  have  the  most  recent  version  of  the  Product  Support 
Manual, please visit the ACR website at 

www.acrelectronics.com

 
©2009  by  ACR  Electronics,  Inc.,  part  of  Cobham  plc.  All  rights  reserved. 
Reproduction  in  whole  or  in  part  is  permitted  only  with  permission  of  ACR 
Electronics, Inc.  
___________________________________________________________________ 
 
Ongoing product improvements may change product specifications without notice. 
 
 
Trademarks or registered trademarks are the property of their respective owners.

 

Содержание 3900

Страница 1: ......

Страница 2: ...ny has four divisions that collectively specialize in the provision of components subsystems and services that keep people safe improve communications and enhance the capability of aerospace and defense platforms CAUTION Before proceeding to install test or use your new ACR Electronics product please read this Product Support Manual in its entirety If you have questions regarding the contents of t...

Страница 3: ...GENERAL _______________________________3 SECTION TWO OPERATING INSTRUCTIONS_______________5 SECTION THREE TESTING AND MAINTENANCE ___________7 APPENDIX A WARRANTY USEFUL LIFE POLICY NOTICES 11 PLEASE READ ALL WARNINGS CAUTIONS AND NOTES CAREFULLY ...

Страница 4: ...rs to assist in non visual battery replacement The case is fabricated of high impact cut resistant thermoplastic material and designed to insure watertight integrity of the main body case The light utilizes a xenon strobe lamp is powered by two AA batteries and is actuated by a magnetic reed switch The light is designed for one handed operation and may be operated by either hand or attached to any...

Страница 5: ... sufficient to fire the xenon flash tube This stepped up voltage is so timed that the flash tube will fire between 40 60 flashes per minute IR filter in storage position ACR P N 4459 Flashguard ACR P N 4463 Strobe lamp Electronics compartment ON OFF magnetic slide switch Lanyard Battery alkaline AA Battery door ACR P N 9338 Blue filter in storage position not visible when stored Figure 1 Slide for...

Страница 6: ...ight With the flashguard shield in the retracted stored position slightly raise the IR filter and rotate it either left right 90 push filter in to lock into place See Figure 2 Figure 2 d IR Light With the flashguard shield in the retracted stored position insure that the IR filter is resting on the top vertical end of the light over the clear lens then push filter down to lock into place See Figur...

Страница 7: ... light to lock it into position While holding the main body case with either hand grasp the flashguard shield with the other hand and pull it up until it stops or a slight locking sound is detected then release This is an indication that the blue filter has been released and fully engaged to its proper operating position See Figure 4 Figure 4 Stored Turn On IR light Raise Shield Turn ON Blue light...

Страница 8: ...tly observe the light flashes during this evaluation This inspection should be performed in a dark room or enclosure If any light fails to meet the 50 10 flash rate requirements check the batteries and if necessary replace both batteries and repeat the test Additionally the battery contacts in the battery well should be checked and if necessary cleaned with a small brush Hold vertical while using ...

Страница 9: ...flashguard and pushing upward until it stops NOTE Standard ambient temperature for performing flash rate test is 70 Fahrenheit A lower temperature may result in somewhat lower flash rates c BA 3058 U battery AA Alkaline or equivalent Currently only a commercial test fixture exists to test the BA 3058 Radio Shack part number 910 2135 Type 22 096 or equivalent Therefore batteries surpassing their li...

Страница 10: ... 5V AA Alkaline 1 Check the battery case for cracks swelling or leakage Replace as necessary 2 CAUTION Do not mix different battery brands 3 CAUTION Do not mix old and new batteries 4 CAUTION Do not mix different battery types e g lithium and alkaine 5 Replace batteries if device is used on a mission or annually 5 Alignment No alignment procedures or special inspection requirements must be perform...

Страница 11: ... each other Then slide the new flashguard in place until it clicks into the locked position b To replace the battery door Unscrew the wire cable from the insert in the battery compartment To install new battery door screw the cable end through the insert in the battery compartment The cable is held in place after the threaded cable end goes all the way through the insert c To replace the IR filter...

Страница 12: ...RB PLB S VDR SSAS USEFUL LIFE POLICY The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers A Product that is 12 or less years old from date of manufacture will be serviced as long as the unit appears fit to be pl...