background image

C

 

A

 

B

 

C

A

B

PREPARATION 

Attach the pump (A) to a sturdy base (table, board, etc.) to prevent it from tipping over. Make sure the
hoses are as straight as possible. 

5.

WARNING: 

This pump CANNOT be submersed in water, and the motor

CANNOT  get  wet  at  all.  Getting  the  motor  wet  could  cause
electrocution, which could lead to serious injury or death! 

NOTICE: 

DO NOT coil or kink the hose

To operate, plug the pump (A) into a GFCI outlet. 

6.

NOTICE: 

This pump can be very loud when plugged in. THIS

IS  NORMAL.  Once  water  begins  to  pump,  the  noise  will
dissipate.  When  the  water  level  has  been  reduced  to
approximately 1/8 in., you MUST UNPLUG THE PUMP. DO
NOT RUN DRY. The pump will be EXTREMELY LOUD when
the pump is no longer pumping water. 

NOTICE:

 If water is not pumped in 30 seconds, unplug the

power cord and check the connection on the two ends of the
inlet  hose  to  make  sure  there  are  no  air  leaks. Then,  add
water into the inlet again and repeat the process. 

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Pump does 
not start or 
run

Pump doesn't
prime

1. Blown fuse
2. Tripped breaker
3. Plug disconnected
4. Corroded plug 
5. Motor overheated

1. Replace fuse
2. Reset breaker
3. Secure plug
4. Clean plug prongs
5. Unplug the power and wait for 30
    minutes,then plug in the power cord

1. Air leak in suction line
2. Impeller clogged
3. Impeller worn or damaged 
4. Impeller dry

1. Repair suction line by tightening
    hose connection
2. Remove blockage
3. Replace impeller
4. Add water to the pump inlet

Flow rate is
too low

1. Hose kinked or coiled 
2. Strainer or hose blocked 
3. Discharge hose too long 
4. Worn impeller

1. Straighten hose 
2. Clean strainer or hose 
3. Shorten the hose (50 ft. max) 
4. Replace the impeller

5

6

Содержание TRP010-2

Страница 1: ... TRP010 2 FOR ENGLISH Pages 02 06 Pages 08 12 WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury If you have any QUESTIONS PROBLEMS MISSING PARTS please call our customer service department at 800 201 1360 before returning to your retailer FOR SPAN...

Страница 2: ... out Running the pump without sufficient water will damage the pump and void the pump s warranty When the pump is running dry it will be EXTREMELY LOUD This is a sign to unplug the pump You must use the included clear suction hose on the inlet of this pump as marked on the pump Always use the suction strainer included with this pump to prevent debris from damaging the pump Do not pump flammable or...

Страница 3: ...property damage 6 Before using the pump check the hose for holes or excess wear which could cause leaks and be sure hose is not kinked or making sharp angles A straight hose allows the pump to move the greatest amount of water quickly 7 Check that all hose connections are tight to minimize leaks 8 Connect the pump DIRECTLY to a grounded GFCI outlet 9 Extension cords may not deliver sufficient volt...

Страница 4: ...lowest point to be pumped 2 NOTICE Make sure the connection is airtight An air leak can cause the pump A to run dry Thread the other end of the suction hose C to the suction inlet of the pump A 3 Make sure the suction hose C and suction strainer B are in the water before plugging in the pump A Thread a 5 8 in or larger garden hose sold separately 50 ft max length onto the discharge outlet of the p...

Страница 5: ...d in 30 seconds unplug the power cord and check the connection on the two ends of the inlet hose to make sure there are no air leaks Then add water into the inlet again and repeat the process TROUBLESHOOTING Problem Possible Cause Corrective Action Pump does not start or run Pump doesn t prime 1 Blown fuse 2 Tripped breaker 3 Plug disconnected 4 Corroded plug 5 Motor overheated 1 Replace fuse 2 Re...

Страница 6: ...1 Screw Impeller cover O ring Impeller Shaft Hose connection Strainer PARTS DIAGRAM PARTS LIST Part No Description 1 2 3 4 5 6 7 2 3 4 5 6 7 ...

Страница 7: ... Modelo TRP010 2 Model TRP010 2 Advertencia Lea cuidadosamente y comprenda todas las INSTRUCCIONES DE MONTAJE Y OPERACIÓN antes de operar Si no se siguen las reglas de seguridad y otras precauciones básicas de seguridad puede resultar en lesiones personales graves Si tiene cualquier PREGUNTAS PROBLEMAS PIEZAS FALTANTES por favor llame a nuestro departamento de servicio al cliente al 800 201 1360 a...

Страница 8: ...to es una señal para desenchufar la bomba Debe utilizar la manguera de succión clara incluida en la entrada de esta bomba tal como se indica en la bomba Utilice siempre el filtro de succión que se incluye con esta bomba para evitar que los desechos dañen la bomba No bombee líquidos inflamables o explosivos como aceite gasolina queroseno etanol etc No lo use en presencia de vapores inflamables o ex...

Страница 9: ... que podría provocar fugas y asegúrese de que la manguera no esté doblada ni haga ángulos agudos Una manguera recta permite que la bomba mueva la mayor cantidad de agua rápidamente 7 Compruebe que todas las conexiones de manguera estén apretadas para minimizar las fugas Asegúrese de que todas las arandelas de manguera estén en su lugar 8 Conecte la bomba DIRECTAMENTE a un tomacorriente GFCI conect...

Страница 10: ...que la conexión esté hermética Una fuga de aire puede hacer que la bomba A funcione en seco Enrosque el otro extremo de la manguera de succión C a la entrada de succión de la bomba A 3 Asegúrese de que la manguera de succión C y el filtro de succión B estén en el agua antes de conectar la bomba A Enrosque una manguera de jardín de 5 8 pulgadas o más grande no incluida en la salida de descarga de l...

Страница 11: ...enrollar ni doblar la manguera Para operar enchufe la bomba A en una toma de corriente GFCI 6 AVISO Esta bomba puede ser muy ruidosa cuando está enchufada ESTO ES NORMAL Una vez que el agua empieza a bombear el ruido se disipará Cuando el nivel de agua se ha reducido a aproximadamente 1 8 pulg DEBE DESENCHAR LA BOMBA NO FUNCIONE SECO La bomba estará EXTREMADAMENTE RUIDOSA cuando la bomba ya no est...

Страница 12: ...1 1 2 3 4 5 6 7 2 3 4 5 6 7 Tornillo Cubierta del impulsor Junta tórica Impulso Eje Conexión de manguera Colador DIAGRAMA DE PIEZAS LISTA DE PARTES Número de pieza Descripción ...

Отзывы: