background image

SAFETY INFORMATION

This pump is designed to pump only water. This pump is designed for portable applications. It can drain
or  remove  water  from  the  following:  flooded  areas,  pool  covers,  clogged  sinks,  waterbeds,  water
basins, boats, stock tanks, etc. It can also be used to fill tanks or water beds. This pump has not been
tested or approved for use in swimming pools or in salt-water marine areas. This pump should not be
used as a replacement for a sump pump.

CAUTION

ADDITIONAL SAFETY PRECAUTIONS 

This pump cannot be used in sewage applications. Doing so will void warranty.

This pump is made of high-strength materials. It will provide trouble-free service for many years when
properly  installed,  maintained,  and  used.  However,  inadequate  electrical  power  to  the  pump,  or
blockage by ice, dirt, or debris may cause the pump to fail, potentially bringing about additional water
damage. To minimize the potential for water damage due to pump failure, please read the section of
this manual regarding common pump problems and remedies or call 800-201-1360

1. Know the pump applications, limitations, and potential hazards.

2. Make certain the electrical power source is adequate for the requirements of the pump.

3. ALWAYS disconnect the power to the pump and drain all water from the system before servicing.

4. Secure the pump on a solid base to prevent the pump from tipping over and possibly falling into the

water

5. Secure the discharge hose before starting the pump. Pump torque may cause an unsecured discharge

hose to “whip”, possibly causing personal injury and/or property damage.

6. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and be sure

hose  is  not  kinked  or  making  sharp  angles. A  straight  hose  allows  the  pump  to  move  the  greatest
amount of water quickly.

7. Check that all hose connections are tight to minimize leaks.

8. Connect the pump DIRECTLY to a grounded, GFCI outlet.

9. Extension cords may not deliver sufficient voltage to the pump motor. If an extension cord must be

used, use no more than a 25 ft., 3-prong, 16 AWG, outdoor-grade cord.

10. Make certain the electrical circuit to the pump is protected by a 5-amp minimum (15-amp maximum)

fuse or circuit breaker.

11. Periodically inspect pump and system components to be sure pump inlets are free of mud, sand, and

debris. DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.

12. Wear safety glasses at all times when working with pumps.

13. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the

workplace, the Occupational Safety and Health Act (OSHA).

14. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved

3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY
CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly installed and grounded
3-prong, grounding-type receptacle. Do not use pump with a 2-prong wall outlet. Replace the 2-prong
outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the
National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified
electrician.

15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord.

Do not use damaged or worn cords.

Содержание TRP010-2

Страница 1: ... TRP010 2 FOR ENGLISH Pages 02 06 Pages 08 12 WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury If you have any QUESTIONS PROBLEMS MISSING PARTS please call our customer service department at 800 201 1360 before returning to your retailer FOR SPAN...

Страница 2: ... out Running the pump without sufficient water will damage the pump and void the pump s warranty When the pump is running dry it will be EXTREMELY LOUD This is a sign to unplug the pump You must use the included clear suction hose on the inlet of this pump as marked on the pump Always use the suction strainer included with this pump to prevent debris from damaging the pump Do not pump flammable or...

Страница 3: ...property damage 6 Before using the pump check the hose for holes or excess wear which could cause leaks and be sure hose is not kinked or making sharp angles A straight hose allows the pump to move the greatest amount of water quickly 7 Check that all hose connections are tight to minimize leaks 8 Connect the pump DIRECTLY to a grounded GFCI outlet 9 Extension cords may not deliver sufficient volt...

Страница 4: ...lowest point to be pumped 2 NOTICE Make sure the connection is airtight An air leak can cause the pump A to run dry Thread the other end of the suction hose C to the suction inlet of the pump A 3 Make sure the suction hose C and suction strainer B are in the water before plugging in the pump A Thread a 5 8 in or larger garden hose sold separately 50 ft max length onto the discharge outlet of the p...

Страница 5: ...d in 30 seconds unplug the power cord and check the connection on the two ends of the inlet hose to make sure there are no air leaks Then add water into the inlet again and repeat the process TROUBLESHOOTING Problem Possible Cause Corrective Action Pump does not start or run Pump doesn t prime 1 Blown fuse 2 Tripped breaker 3 Plug disconnected 4 Corroded plug 5 Motor overheated 1 Replace fuse 2 Re...

Страница 6: ...1 Screw Impeller cover O ring Impeller Shaft Hose connection Strainer PARTS DIAGRAM PARTS LIST Part No Description 1 2 3 4 5 6 7 2 3 4 5 6 7 ...

Страница 7: ... Modelo TRP010 2 Model TRP010 2 Advertencia Lea cuidadosamente y comprenda todas las INSTRUCCIONES DE MONTAJE Y OPERACIÓN antes de operar Si no se siguen las reglas de seguridad y otras precauciones básicas de seguridad puede resultar en lesiones personales graves Si tiene cualquier PREGUNTAS PROBLEMAS PIEZAS FALTANTES por favor llame a nuestro departamento de servicio al cliente al 800 201 1360 a...

Страница 8: ...to es una señal para desenchufar la bomba Debe utilizar la manguera de succión clara incluida en la entrada de esta bomba tal como se indica en la bomba Utilice siempre el filtro de succión que se incluye con esta bomba para evitar que los desechos dañen la bomba No bombee líquidos inflamables o explosivos como aceite gasolina queroseno etanol etc No lo use en presencia de vapores inflamables o ex...

Страница 9: ... que podría provocar fugas y asegúrese de que la manguera no esté doblada ni haga ángulos agudos Una manguera recta permite que la bomba mueva la mayor cantidad de agua rápidamente 7 Compruebe que todas las conexiones de manguera estén apretadas para minimizar las fugas Asegúrese de que todas las arandelas de manguera estén en su lugar 8 Conecte la bomba DIRECTAMENTE a un tomacorriente GFCI conect...

Страница 10: ...que la conexión esté hermética Una fuga de aire puede hacer que la bomba A funcione en seco Enrosque el otro extremo de la manguera de succión C a la entrada de succión de la bomba A 3 Asegúrese de que la manguera de succión C y el filtro de succión B estén en el agua antes de conectar la bomba A Enrosque una manguera de jardín de 5 8 pulgadas o más grande no incluida en la salida de descarga de l...

Страница 11: ...enrollar ni doblar la manguera Para operar enchufe la bomba A en una toma de corriente GFCI 6 AVISO Esta bomba puede ser muy ruidosa cuando está enchufada ESTO ES NORMAL Una vez que el agua empieza a bombear el ruido se disipará Cuando el nivel de agua se ha reducido a aproximadamente 1 8 pulg DEBE DESENCHAR LA BOMBA NO FUNCIONE SECO La bomba estará EXTREMADAMENTE RUIDOSA cuando la bomba ya no est...

Страница 12: ...1 1 2 3 4 5 6 7 2 3 4 5 6 7 Tornillo Cubierta del impulsor Junta tórica Impulso Eje Conexión de manguera Colador DIAGRAMA DE PIEZAS LISTA DE PARTES Número de pieza Descripción ...