background image

OMNISTAND™ USER MANUAL   

 

 

 

 

 

 

 

 

         

9

  

 

 
 
 
 
 

COPYRIGHT © 2016, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED. 

Biocompatibility 

 

 

All components and optional accessories of the OmniStand™ that the user might come in contact with when 
using the device as intended are designed to meet the biocompatibility requirements of the applicable standards.  

 

 
Training Requirements 

 

Staff members who have gained their skills and expertise by means of professional medical training, professional 
experience, or by means of instruction/training by the manufacturer are deemed able to assess relevant safety 
regulations and recognize potential risks. 
 

 

Do not operate this device until the User Manual has been carefully read and is understood. 

 

Before you start the OmniStand™ exercise programs, consult the User Manual and understand the specific 
Warnings and Precautions related to the safe use of the device.  

 

Review and understand the section marked Operational Guidelines before operating the OmniStand™. 

 

Review and understand the proper use of the device controls and proper setup, features, and adjustment 
requirements of the OmniStand™. 

 

A member of your ACP team will install and configure the device before training. ACP will conduct a train-the-
trainer style education process when the OmniStand™ is delivered.  

 

During training: 

o

 

Observe proper safety protocol by sufficiently securing patient per user manual instructions 

o

 

Start to exercise slowly 

o

 

Gradually increase exercise demands according to individual exerciser performances 

o

 

Avoid overstraining exercisers 

 

Exerciser Requirements 
 

Exercisers/Users must be instructed by trained therapist on the correct and safe use of the OmniStand™. The 
therapist is responsible for the safe and correct use of the device by the user. 
 

o

 

The user's lower extremities are able to support his/her weight. 

o

 

To stand in the OmniStand™ without assistance: 

 

The user is able to stand and actively straighten their upper body and safely and 
effectively maintain a sufficient upright posture during the exercise session. 

o

 

If the user is able to control the OmniStand™ without assistance: 

 

Make sure that a trained assistant supervises the training. 

o

 

The OmniStand™ is not suitable for: 

 

Diagnosis 

 

Monitoring 

 

Measuring 

 

Содержание OMNISTAND

Страница 1: ...lose or exploit this manual except as for purposes of using the equipment as contemplated by the Purchase or Lease Agreement ACCELERATED CARE PLUS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MANUAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Accelerated Care Plus shall not be liable for errors contained herein or for incidental ...

Страница 2: ...2 OMNISTAND USER MANUAL COPYRIGHT 2016 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED ...

Страница 3: ...stems Our MEGAPULSE NEUROPROBE OMNISTIM OMNISOUND OMNITEST OMNICYCLE OMNIVR OMNISTAND OMNISWD OMNIVERSA and SYNCHRONY DYSPHAGIA SOLUTIONS BY ACP represent the most recent worldwide advances available for therapeutic application of electro medical devices and other rehabilitation technology ACP is internationally recognized for its contribution to research in the development of medical applications...

Страница 4: ...TROL EQUIPMENT AND PRINCIPLES OF USE 17 Definitions 17 Universal Precautions Body Substance Isolation 17 Cleaning Disinfecting of the OmniStand 17 Cleaning and Low Level Disinfection 17 Intermediate Level Disinfection and Barriers 17 Use of Barriers Intermediate Level Disinfection 18 PREVENTIVE MAINTENANCE AND GOOD OPERATING PRACTICES 18 Replacing the Balance Unit 18 Replacing the Pelvic Safety St...

Страница 5: ...RESERVED Symbols on the Product Symbol Used for Symbol Used for Serial number Date of manufacture Manufacturer Consult instructions for use CE mark of confidence Observe the user manual Caution consult accompanying documents Protect the product from humidity Maximum body weight ...

Страница 6: ...6 OMNISTAND USER MANUAL COPYRIGHT 2016 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED ...

Страница 7: ... stroke Parkinson s disease Chronic heart failure CHF Chronic obstructive pulmonary Disease COPD Muscle disuse atrophy The OmniStand can be used in conjunction with other biofeedback devices to encourage greater patient participation exercise effort and or exercise duration Contraindications Users weighing more than 309lbs 140 kg Users shorter than 4 5 135cm Users taller than 6 7 200cm Users with ...

Страница 8: ...sitioning and force applied through the extremities are within safe limits for the individual exerciser Caution should be taken with any patient exhibiting psychological or physical hypersensitivity to the therapeutic treatment Several attempts should be made to place them at ease so that their confidence and cooperation can be gained during the treatment Children must be constantly supervised whe...

Страница 9: ... the device controls and proper setup features and adjustment requirements of the OmniStand A member of your ACP team will install and configure the device before training ACP will conduct a train the trainer style education process when the OmniStand is delivered During training o Observe proper safety protocol by sufficiently securing patient per user manual instructions o Start to exercise slow...

Страница 10: ...tor and must not be carried up or down stairs To move the unit unlock the wheels and push it in front of you Introduction The OmniStand is a dynamic balance system designed specifically for individuals who have poor standing tolerance and abnormalities with static or dynamic standing balance The OmniStand creates a fall safe environment that can be used with supervised exercise and be combined wit...

Страница 11: ...Functions A Upper pipe frame B Stay tube C Abdominalcushion D Vertical pipe of balance unit E Release lever for dynamic standing function F Height adjustment of simple knee support G Transport castors with brake H Balance unit with settings for spring resistance I Base unit J Knee support K Tread unit ...

Страница 12: ...ndent on each user s goals and health status Basic Operational Sequence Caution Risk of injury due to insufficient preparation Before starting any exercise make sure that the OmniStand is properly assembled and fully operational Disinfect the OmniStand before every training Note Markings on upper pipe frame and knee support simplify horizontal adjustment Before every exercise session adjust settin...

Страница 13: ...revent overextension of joints and damage to muscles tendons or ligaments Note The simple knee support provides support for the user when rising and standing or during balance exercise Adjusting the simple knee support does not require any tools In order to be able to lower the user quickly put a chair or wheelchair directly behind the OmniStand during the training session Setting the height Loose...

Страница 14: ...n Attach belt buckles G in securing system K on stay tubes o Select the same position for left and right side Make sure that buckle audibly clicks into place Make sure that pelvic safety strap runs below stay tubes Shorten pelvic safety strap by pulling on straps H on either side and a second set below If necessary lengthen pelvic safety strap by opening clamping locks I upper or lower Basic Pelvi...

Страница 15: ...session Lift OmniStand by upper pipe frame on left and right side If it is possible to remove the vertical pipe from the balance unit then training with the OmniStand is not allowed Contact ACP Customer Service Set release lever N to 2 1 or 0 on both vertical pipes Make sure that release lever latches in Assure release lever is set to the same position on both sides Position 2 dynamic standing fun...

Страница 16: ...Always position chair wheelchair directly behind exerciser Lock brakes of wheelchair Note When using the OmniStand it may be necessary to lift or lower the exerciser with the help of an assistant who is trained for the procedure To lift the user Set height of the knee support and upper pipe frame Before starting the training session make sure that transport castors with brake wheel locks are appli...

Страница 17: ...trol policy ACP recommends the following guidelines Cleaning and Low Level Disinfection This is a recommended daily housekeeping practice to keep the equipment clean and free of contaminants which could contribute to transmission of infection The following practices are recommended for use when treating intact skin without the presence of physiologic fluids such as blood and urine Clean equipment ...

Страница 18: ...et up the patient per guidelines for the therapy 6 Provide therapy as appropriate 7 Discard all disposables 8 With clean gloves remove the plastic film from the unit and discard 9 Intermediate disinfect the OmniStand unit prior to the next therapy application Preventive Maintenance and Good Operating Practices Preventive maintenance is recommended to be performed at least annually This should incl...

Страница 19: ...itions for transport delivery F C Rh hPa 13 F 25 C to 158 F 70 C 5 to 93 Rh 700 to 1 060 hPa Suitable for users with Body height Body weight Height Min Height Max Max Weight 53in 135cm 78in 200cm 309lbs 140kg Materials Used Steel stainless steel aluminum rubber plastics POM PA6 ABS PE Economic life time OmniStand Yrs 5 to 7 Standards MDD 93 42 EEC DIN EN ISO 13485 DIN EN 12182 Proper Disposal Prop...

Страница 20: ...MNISTAND DYNAMIC BALANCE SYSTEM Shipping Weight 178 lbs 81 kg ACCESSORY ITEM NO DESCRIPTION 81582 OmniStand Premium Pelvic Safety Belt with Support Sling 49522 OmniStand Basic Pelvic Safety Belt 84315 OmniStand Table Top 81160 OmniStand Tread Extension Ramp 290A005 509 OmniStand User Manual This item is an optional accessory and may not be included with the unit ...

Страница 21: ... 4 x 6 perforated sheets 1200 sheets roll 66431 Barrier Film for Surfaces Infection Control 6 x 9 perforated Sheets 800 sheets roll 50593 Barrier Film for Surfaces Infection Control 12 x 14 perforated Sheets 514 sheets roll 63574 Barrier Film 3 Tubing 1200 roll 55536 Super Sani Cloth Single Use Packets 50 pk bx 44425 Super Sani Cloth Tub 160 Tub 96849 Sani Cloth w Bleach Tub 75 wipes tub ...

Страница 22: ...uding serial number alteration 4 The product was used with accessories and or supplies including electrodes not approved by ACP for use with the product Warranty Period The following coverage is provided at no additional cost to the Buyer New Equipment Product Products purchased as new from ACP are warranted against manufacturer s defects in material and workmanship for a period of one 1 year from...

Страница 23: ...o a minimum service and handling fee IMPORTANT DO NOT SHIP THE EQUIPMENT TO ACP SERVICE CENTER WITHOUT FIRST SECURING AUTHORIZATION TO DO SO PLEASE CALL CUSTOMER SERVICE AT 800 350 1100 FOR AUTHORIZATION EQUIPMENT SENT IN WITHOUT AUTHORIZATION FROM ACP CUSTOMER SUPPORT WILL NOT BE ACCEPTED RETURNED MATERIALS ADDRESS Accelerated Care Plus Leasing Attn ACP Service Center 4999 Aircenter Circle Suite ...

Страница 24: ......

Отзывы: