background image

Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires it. 

 

16500024 

 

October 2013 

 

©2013 ACP, Inc.

 

6

 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 
test method requires precision measurements and equipment that is not practical to be performed in the field. Using 
the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

 

1000 ml test container and thermometer. 

 

Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

 

Low line voltage will cause low temperature rise / power output. 

 

Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 

 

This test and results are not a true IEC705 test procedures and are only intended to provide servicers with 
an easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

 

Water temperature should be approximately 60

°

F / 16

°

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

 

Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

5.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

6.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

7.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1 - 6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time 

Cooking 

Cooking 

Cooking 

Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10 ................. 1000 

20 ................. 2000 

5  .............. 1000 

11 ............ 2000 

11 ................. 1100 

21 ................. 2100 

5.5 ............ 1100 

11.5 ......... 2100 

12 ................. 1200 

22 ................. 2200 

6.5 ............ 1200 

12 ............ 2200 

14 ................. 1400 

24 ................. 2400 

7.5 ............ 1400 

13 ............ 2400 

17 ................. 1700 

25 ................. 2500 

9.5 ............ 1700 

13.5 ......... 2500 

18 ................. 1800 

27 ................. 2700 

10 ............. 1800 

15 ............ 2700 

19 ................. 1900 

30 ................. 3000 

10.5 .......... 1900 

16.5 ......... 3000 

 

 

Содержание MFS18TS

Страница 1: ...e servicing unless testing requires it Models RFS18TS MFS18TS MFS18TSSA Power Source Voltage AC 208 240 VAC 208 240 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R BS1363 A Plug 6 20P BS1363 A Power Output Nominal microwave energy IEC705 1800 Watts 1800 Watts Minimum temperature rise T 18ºF 7 7ºC 18ºF 7 7ºC Operating Frequency 2450 MHz 245...

Страница 2: ...towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ω Each terminal to ground measures Infinite resistance Note This test is not concl...

Страница 3: ...ite Ω Infinite Ω Indicates continuity Indicates continuity Lamp receptacle Test continuity of receptacle terminals Indicates continuity with bulb installed Wire Harness Test continuity of wires Indicates continuity Electronic Control Panel Service Test Mode Open door Press and Hold pad 3 for 5 seconds to enter service test mode Press Pad 1 Press Pad 2 Press Pad 3 Press Pad 4 Press Pad 5 Press Pad ...

Страница 4: ...nic Control RFS18TS Keyboard assembly 1 2 3 4 5 6 7 8 9 10 11 Continuity is indicated as 100 Ω and below Pad 0 1 2 3 4 5 6 7 8 9 HOLD 0 DEFROST 20 MEDIUM 50 MED HI 70 TIME ENTRY STOP RESET START Trace 1 8 2 8 3 8 4 8 5 8 6 8 7 8 1 9 2 9 3 8 1 10 2 10 3 10 4 10 5 10 6 10 7 10 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Co...

Страница 5: ...ts Tab 2 to CN1 Pin 3 208 240 VAC Power from Oven TCO All Conditions Volts CN1 Pin 1 Black wire to ground 208 240 VAC Power to Oven Light Standby Ready Cook Volts Volts Volts CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 208 240 VAC 0 VAC 0 VAC Power to Blower Motor Standby Ready Cook Volts Volts Volts CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 208 240 VAC 0 VAC 0 VAC Seco...

Страница 6: ...NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle rem...

Страница 7: ... 230V NOTE 1 DOOR IS OPENED 2 WIRE COLOR SYMBOL COLOR BLACK BROWN BLUE GREEN PINK RED WHITE YELLOW BK BN BL GN PK RD WH YL YL FUSE BM OVEN TCO MOTOR BLOWER BTM STIRRER MOTOR BTM PRIMARY INTERLOCK SWITCH BTM INTERLOCK MONITOR SWITCH TOP MAGNETRON SEE HV CIRCUIT BTM MAGNETRON SEE HV CIRCUIT MAGNETRON H V CAPACITOR H V DIODE CHOKE FILTER HV CIRCUIT 2 PLACES RD WH BL WH BK BL BK BK WH BK RD WH BN GN B...

Отзывы: