Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires it. 

 

16500024 

 

October 2013 

 

©2013 ACP, Inc.

 

2

 

Illustration 

Component 

Testing  

Results 

 

 

 

Thermal cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity TCO ...........................................  
 
Magnetron TCO ....................................  

 
 
Opens at 230

°

F (110

°

C) 

 
Closed at 140

°

F (60

°

C) and  

   Opens at 320

°

F (160

°

C) 

 

 

Diode 

Discharge Capacitor

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be 
measured in one direction and 50K

 

or more in the opposite direction. 
 

NOTE:

 Ohmmeter must contain a 

battery of 6 volts minimum. 

 

 

Capacitor 

Discharge Capacitor

 

 
Remove wires from capacitor terminals 
and connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
Also check between each terminal and 
capacitor case. 

 
 
Between Terminals: Meter should 
momentarily deflect towards zero 
then return to over 5 M

. If no 

deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 
Terminal to Case: Infinite resistance 

 

 

Magnetron 

Discharge Capacitor

 

 
Remove wires from magnetron and 
connect ohmmeter to terminals. Also 
check between each terminal and 
ground. 

Between Terminals: Less than 1 

 

 
Each terminal to ground measures 
Infinite resistance. 

Note:

 This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

 

Blower motor 

Remove all wires from motor. 
 
Measure resistance across coil .............  

 
 
Approximately 28 – 35 

 

 

 

Stirrer motor 

Remove all wires from motor. 
 
Measure resistance across terminals ....  

 
 
Approximately 12 – 14 K

 

 

Filament

Secondary

Primary

 

Transformer 

 

Discharge Capacitor 

Remove all wires from terminals. 
 
Measure resistance from: 

Primary ................................................  
Filament ...............................................  
Secondary to Ground screw on 
transformer stack .................................  

 
 
 
 
Less than <1 

 

Less than <1 

 

 
 
Approximately 70-80 

 

 

Noise filter board 

Power In terminals ................................  
Power Out terminals..............................  

240 VAC 
240 VAC 
If no power in, check power outlet. 
If no power out, check fuses. 

 

Circuit Protector 

Measure resistance across terminals ....  

Between Terminals: Less than 1 

 

 

Содержание MFS18TS

Страница 1: ...e servicing unless testing requires it Models RFS18TS MFS18TS MFS18TSSA Power Source Voltage AC 208 240 VAC 208 240 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R BS1363 A Plug 6 20P BS1363 A Power Output Nominal microwave energy IEC705 1800 Watts 1800 Watts Minimum temperature rise T 18ºF 7 7ºC 18ºF 7 7ºC Operating Frequency 2450 MHz 245...

Страница 2: ...towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ω Each terminal to ground measures Infinite resistance Note This test is not concl...

Страница 3: ...ite Ω Infinite Ω Indicates continuity Indicates continuity Lamp receptacle Test continuity of receptacle terminals Indicates continuity with bulb installed Wire Harness Test continuity of wires Indicates continuity Electronic Control Panel Service Test Mode Open door Press and Hold pad 3 for 5 seconds to enter service test mode Press Pad 1 Press Pad 2 Press Pad 3 Press Pad 4 Press Pad 5 Press Pad ...

Страница 4: ...nic Control RFS18TS Keyboard assembly 1 2 3 4 5 6 7 8 9 10 11 Continuity is indicated as 100 Ω and below Pad 0 1 2 3 4 5 6 7 8 9 HOLD 0 DEFROST 20 MEDIUM 50 MED HI 70 TIME ENTRY STOP RESET START Trace 1 8 2 8 3 8 4 8 5 8 6 8 7 8 1 9 2 9 3 8 1 10 2 10 3 10 4 10 5 10 6 10 7 10 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Co...

Страница 5: ...ts Tab 2 to CN1 Pin 3 208 240 VAC Power from Oven TCO All Conditions Volts CN1 Pin 1 Black wire to ground 208 240 VAC Power to Oven Light Standby Ready Cook Volts Volts Volts CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 208 240 VAC 0 VAC 0 VAC Power to Blower Motor Standby Ready Cook Volts Volts Volts CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 208 240 VAC 0 VAC 0 VAC Seco...

Страница 6: ...NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle rem...

Страница 7: ... 230V NOTE 1 DOOR IS OPENED 2 WIRE COLOR SYMBOL COLOR BLACK BROWN BLUE GREEN PINK RED WHITE YELLOW BK BN BL GN PK RD WH YL YL FUSE BM OVEN TCO MOTOR BLOWER BTM STIRRER MOTOR BTM PRIMARY INTERLOCK SWITCH BTM INTERLOCK MONITOR SWITCH TOP MAGNETRON SEE HV CIRCUIT BTM MAGNETRON SEE HV CIRCUIT MAGNETRON H V CAPACITOR H V DIODE CHOKE FILTER HV CIRCUIT 2 PLACES RD WH BL WH BK BL BK BK WH BK RD WH BN GN B...

Отзывы: