Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires it. 

 

October 2013 

 

16500024 

©2013 ACP, Inc. 

 

3

 

Illustration 

Component 

Testing  

Results 

 

1

2

3

4

5

6

 

Interlock switch assembly 
 

Primary

Monitor

Secondary

 

Disconnect wires to switch. 
 
With door open measure resistance from: 
 

Monitor - Terminal 3 - 4 .........................  

 

Primary - Terminal 1 - 2 .........................  

 

Secondary - Terminal 5 - 6 ....................  

 
With door closed measure resistance from: 
 

Monitor - Terminal 3 - 4 .........................  

 

Primary - Terminal 1 - 2 .........................  

 

Secondary - Terminal 5 - 6 ....................  

 

After verifying or replacing the 
module, reconnect wires to switch 
and check operation of monitor circuit 
before operating the oven.

 

 
 
 
Indicates continuity  
Infinite 

 

Infinite 

 

 
 
Infinite 

  

Indicates continuity 
Indicates continuity 

 

Lamp receptacle 

Test continuity of receptacle terminals. 

Indicates continuity with bulb 
installed. 

 

Wire Harness 

Test continuity of wires 

Indicates continuity 

 

Electronic Control Panel 

 

Service Test Mode: 

Open door, Press and Hold pad 3 for 5 
seconds to enter service test mode. 

Press Pad 1 ................................................ 
 
Press Pad 2 ................................................ 
 
 
Press Pad 3 ................................................ 
Press Pad 4 ................................................ 
 
Press Pad 5 ................................................ 
Press Pad 6 ................................................ 
 
Press Pad 7 ................................................ 
Press Pad 8 ................................................ 
Press Pad 9 ................................................ 
Press Pad 0 ................................................ 
Stop/Reset Pad ........................................... 

SERVICE appears in the display 
 
Indicates number of hours 
magnetron has been turned on 

Indicates number of times 
magnetron tube has been turned 
on and off 
Indicates number of door cycles 
CLEAR (Press START pad to 

reset service data.) 

Indicates amperage (Top Mag) 
Indicates amperage (Bottom Mag) 
 
RESET (Clear Service Alarm) 
N/A 
N/A 
N/A 
Exit Service Test Mode 

 

Error codes: 

E-08

 ............................................................ 

E-09

 ............................................................ 

E-10

 ............................................................ 

Replace Control Board 
Replace Control Board 
Shorted or Open Keypad – Test 
and replace if necessary 

 

 

Содержание MFS18TS

Страница 1: ...e servicing unless testing requires it Models RFS18TS MFS18TS MFS18TSSA Power Source Voltage AC 208 240 VAC 208 240 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R BS1363 A Plug 6 20P BS1363 A Power Output Nominal microwave energy IEC705 1800 Watts 1800 Watts Minimum temperature rise T 18ºF 7 7ºC 18ºF 7 7ºC Operating Frequency 2450 MHz 245...

Страница 2: ...towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ω Each terminal to ground measures Infinite resistance Note This test is not concl...

Страница 3: ...ite Ω Infinite Ω Indicates continuity Indicates continuity Lamp receptacle Test continuity of receptacle terminals Indicates continuity with bulb installed Wire Harness Test continuity of wires Indicates continuity Electronic Control Panel Service Test Mode Open door Press and Hold pad 3 for 5 seconds to enter service test mode Press Pad 1 Press Pad 2 Press Pad 3 Press Pad 4 Press Pad 5 Press Pad ...

Страница 4: ...nic Control RFS18TS Keyboard assembly 1 2 3 4 5 6 7 8 9 10 11 Continuity is indicated as 100 Ω and below Pad 0 1 2 3 4 5 6 7 8 9 HOLD 0 DEFROST 20 MEDIUM 50 MED HI 70 TIME ENTRY STOP RESET START Trace 1 8 2 8 3 8 4 8 5 8 6 8 7 8 1 9 2 9 3 8 1 10 2 10 3 10 4 10 5 10 6 10 7 10 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Co...

Страница 5: ...ts Tab 2 to CN1 Pin 3 208 240 VAC Power from Oven TCO All Conditions Volts CN1 Pin 1 Black wire to ground 208 240 VAC Power to Oven Light Standby Ready Cook Volts Volts Volts CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 CN1 Pin 4 to Pin 1 208 240 VAC 0 VAC 0 VAC Power to Blower Motor Standby Ready Cook Volts Volts Volts CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 CN1 Pin 5 to Pin 1 208 240 VAC 0 VAC 0 VAC Seco...

Страница 6: ...NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle rem...

Страница 7: ... 230V NOTE 1 DOOR IS OPENED 2 WIRE COLOR SYMBOL COLOR BLACK BROWN BLUE GREEN PINK RED WHITE YELLOW BK BN BL GN PK RD WH YL YL FUSE BM OVEN TCO MOTOR BLOWER BTM STIRRER MOTOR BTM PRIMARY INTERLOCK SWITCH BTM INTERLOCK MONITOR SWITCH TOP MAGNETRON SEE HV CIRCUIT BTM MAGNETRON SEE HV CIRCUIT MAGNETRON H V CAPACITOR H V DIODE CHOKE FILTER HV CIRCUIT 2 PLACES RD WH BL WH BK BL BK BK WH BK RD WH BN GN B...

Отзывы: