background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Tone 

Number 

 

 

Tone Description 

 

Switch 

Settings 

1 2 3 4 5 6 

 

Second 

Stage 

Alarm 

 

Third 

Stage 

alarm 

 

Tone 1 

Tone 2 

Tone 3 

Tone 4 

Tone 5 

Tone 6 

Tone 7 

Tone 8 

Tone 9 

Tone 10 

Tone 11 

Tone 12 

Tone 13 

Tone 14 

Tone 15 

Tone 16 

Tone 17 

Tone 18 

Tone 19 

Tone 20 

Tone 21 

Tone 22 

Tone 23 

Tone 24 

Tone 25 

Tone 26 

Tone 27 

Tone 28 

Tone 29 

Tone 30 

Tone 31 

Tone 32 

Tone 33 

Tone 34 

Tone 35 

Tone 36 

Tone 37 

Tone 38 

Tone 39 

Tone 40 

Tone 41 

Tone 42 

Tone 43 

Tone 44 

Tone 45 

Tone 46 

Tone 47 

Tone 48 

Tone 49 

 

 Continuous 340Hz 

 Alternating 800/1000Hz @ 0.25s intervals 

 Slow whoop 500/1200Hz @ 0.3Hz with 0.5s gap repeated 

 Sweeping 500/1000Hz @ 1Hz 

 Continuous 2400Hz 

 Sweeping 2400/2900Hz @ 7Hz 

 Sweeping 2400/2900Hz @ 1Hz 

 Siren 500/1200/500Hz @ 0.3Hz 

 Sawtooth 1200/500Hz @ 1Hz - 

D.I.N.

 

 Alternating 2400/2900Hz @ 2Hz 

 Intermittent 1000Hz @ 1Hz 

 Alternating 800/1000Hz @ 0.875Hz 

 Intermittent 2400Hz @ 1Hz 

 Intermittent 800Hz 0.25s ON, 1s OFF 

 Continuous 800Hz 

 Intermittent 660Hz 150Ns ON, 150ms OFF 

 Alternating 544Hz (100ms) / 440Hz (400ms) – 

NFS 32-001

 

 Intermittent 660Hz 1.8s ON, 1.8s OFF 

 Sweep 1400Hz to1600Hz up 1s 1600Hz to 1400Hz down 0.5s 

 Continuous 660Hz 

 Alternating 554/440Hz @ 1Hz 

 Intermittent 544Hz @ 0.875Hz 

 Intermittent 800Hz @ 2Hz 

 Sweeping 800/1000Hz @ 50Hz 

 Sweeping 2400/2900Hz @ 50Hz 

 Simulated bell 

 Continuous 554Hz 

 Continuous 440Hz 

 Sweeping 800/1000Hz @ 7Hz 

 Continuous 300Hz 

 Sweeping 660/1200 @ 1Hz 

 Two Tone Chime 

  Intermittent 745Hz 

  Alternating 1000/2000Hz @ 0.5s – 

Singapore 

  420Hz @ 0.625s - 

Australian Alert

 

  500-1200Hz 3.75s / 0.25s - 

Australian Evacuate

 

  Continuous 1000Hz  

  Continuous 2000Hz  

  Intermittent 800Hz 0.25s ON 1s OFF 

  Alternating 544Hz (100ms) / 440Hz (400ms) – 

NFS 32-001

 

  Motor Siren – Slow rise to 1200Hz 

  Motor Siren – Slow rise to 800Hz 

  Continuous 1200Hz  

  Motor Siren – Slow rise to 2400Hz 

  Intermittent 1000Hz 1s ON, 1s OFF 

  Sawtooth 1200/500Hz @ 1Hz - 

D.I.N.

 

(PFEER P.T.A.P)

 

  Intermittent 1000Hz 1s ON, 1s OFF – 

PFEER General Alarm

 

  420Hz @ 0.625s - 

Australian Alert

 

  500-1200Hz 3.75s / 0.25s - 

Australian Evacuate

 

 

0 0 0 0 0 0 

1 0 0 0 0 0 

0 1 0 0 0 0 

1 1 0 0 0 0 

0 0 1 0 0 0 

1 0 1 0 0 0 

0 1 1 0 0 0 

1 1 1 0 0 0 

0 0 0 1 0 0 

1 0 0 1 0 0 

0 1 0 1 0 0 

1 1 0 1 0 0 

0 0 1 1 0 0 

1 0 1 1 0 0 

0 1 1 1 0 0 

1 1 1 1 0 0 

0 0 0 0 1 0 

1 0 0 0 1 0 

0 1 0 0 1 0 

1 1 0 0 1 0 

0 0 1 0 1 0 

1 0 1 0 1 0 

0 1 1 0 1 0 

1 1 1 0 1 0 

0 0 0 1 1 0  

1 0 0 1 1 0 

0 1 0 1 1 0 

1 1 0 1 1 0 

0 0 1 1 1 0 

1 0 1 1 1 0 

0 1 1 1 1 0 

1 1 1 1 1 0 

0 0 0 0 0 1 

1 0 0 0 0 1 

0 1 0 0 0 1 

1 1 0 0 0 1 

0 0 1 0 0 1 

1 0 1 0 0 1 

0 1 1 0 0 1 

1 1 1 0 0 1 

0 0 0 1 0 1 

1 0 0 1 0 1 

0 1 0 1 0 1 

1 1 0 1 0 1 

0 0 1 1 0 1 

1 0 1 1 0 1 

0 1 1 1 0 1 

1 1 1 1 0 1 

0 0 0 0 1 1 

 

Tone 2 

Tone 17 

Tone 2 

Tone 6 

Tone 3 

Tone 7 

Tone 10 

Tone 2 

Tone 15 

Tone 7 

Tone 2 

Tone 4 

Tone 15 

Tone 4 

Tone 2 

Tone 18 

Tone 2 

Tone 2 

Tone 2 

Tone 2 

Tone 2 

Tone 2 

Tone 6 

Tone 29 

Tone 29 

Tone 2 

Tone 26 

Tone 2 

Tone 7 

Tone 2 

Tone 26 

Tone 26 

Tone 2  

Tone 38 

Tone 36 

Tone 35 

Tone 9 

Tone 34 

Tone 23 

Tone 31 

Tone 2 

Tone 2 

Tone 2 

Tone 2 

Tone 38 

Tone 47 

Tone 46 

Tone 49 

Tone 26 

 

 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 20 

Tone 5 

Tone 5 

Tone 5 

Tone 2 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 27 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 15 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 5 

Tone 15 

Tone 5  

Tone 45  

Tone 5 

Tone 5  

Tone 45  

Tone 45  

Tone 17  

Tone 27  

Tone 5  

Tone 5  

Tone 5  

Tone 5  

Tone 34 

Tone 37 

Tone 37 

Tone 5 

Tone 37 

 

 
 

 

Tone Selection

 

– To select the required first stage tone set the tone switches 1 to 6 (see 

Fig 2) to the tone setting shown in the table below. The table also shows which 2

nd

 and 3

rd

 

stage tones are available for use with the selected first stage tone if more than one tone 
output stage is required. 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание IS-D105

Страница 1: ...ated device as referred to by Directive 94 9 EC Annex II clause 1 5 3 Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice 4 Repair of this equipment shall only be carried out by the manufacturer or in accordance with the applicable code of practice 5 The certification of this equipment relies on the following material...

Страница 2: ...pply voltage is available 3 2 Terminals S2 and S3 When terminals S2 or S3 are connected to 0V terminal the sounder output tone changes to the second or third stage alarm respectively The input safety parameters for these terminals are Ui 28V Ii 0mA Because the permitted input current is zero these terminals may only be connected to a diode return barrier an intrinsically safe relay or a galvanic i...

Страница 3: ...Single stage alarm If the control switch is in the positive supply or the power supply is being turned on and off only a single channel Zener barrier is required as shown in Fig 3 This circuit may also be used if the sounder is being controlled by a mechanically activated switch on the hazardous area side of the barrier Fig 4 Single stage alarm using single channel barrier If the control switch mu...

Страница 4: ...S D105 sounder second and third stages may be activated by using Galvanically Isolated Relays that have output parameters within the limits specified in section 4 4 which have been certified Ex ia by an EC Notified Body Fig 8 Multi stage alarm using galvanic isolated relays 7 Cable Parameters The maximum permitted cable parameters are as specified on the certificate of the Zener barrier or galvani...

Страница 5: ...en Slow rise to 2400Hz Intermittent 1000Hz 1s ON 1s OFF Sawtooth 1200 500Hz 1Hz D I N PFEER P T A P Intermittent 1000Hz 1s ON 1s OFF PFEER General Alarm 420Hz 0 625s Australian Alert 500 1200Hz 3 75s 0 25s Australian Evacuate 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 ...

Отзывы: