Fragments of Teflon tape or pipe sealant residue can 
interfere with the proper operation of this unit.  Ensure 
pipe sealant methods do not cause contamination in the 
system.

STEP ONE: PEDESTAL

3. Pipe sealant or Teflon tape for sealing water connections.

Refer to Rough-in for location of supply and drain lines.

INSTALLATION INSTRUCTIONS:

3. Re-position assembly and install mounting bolts and 

washers.

Heat Trace cable used on this model is intended to 
prevent freezing and will not provide tempered (heated) 
water. It is recommended to supply this combination 
shower assembly with a tempering system in compliance 
with ANSI Z358.1.

6. Tubing can be connected to the outlet of the Freeze 

Protection Valve if desired. Make sure the tubing is not 
kinked & draining water will not freeze.

Use hand tools and wrenches in a manner which will 
prevent marring finished surfaces.  Strap wrenches or 
tools with plastic jaw linings are highly recommended.

1. Position center of pedestal assembly “A” a minimum of 

1'-8” from all walls.  While holding the assembly in 
position, mark floor flange mounting hole positions.

STEP TWO: SUPPLY AND SANITARY DRAIN 
CONNECTION

2. Make sure proper drainage is supplied nearby.

1. Install necessary pipe fittings (supplied by others) to 

make connection to 1 ¼” NPT supply union w/ potable 
water supply line. Either top or bottom supply may be 
used.

Supplies required: (not provided by Acorn)                            

2. Floor fastener anchors, washers and bolts.

IMPORTANT: FLUSH WATER SUPPLY LINES PRIOR TO 
CONNECTION TO SAFETY EQUIPMENT.

1. Wall fasteners for signage mounting.

NOTES:

 

Bottom of shower head must be between 82”-96” from 
finished floor in order to meet ANSI Z358.1

Prior to beginning assembly, TURN OFF water supply to 
1 ¼” potable water supply line.

Note: Refer to Rough-In for supply line locations.

2. Remove assembly and install appropriate floor anchors 

to receive mounting bolts (supplied by others).

3. Install supply union not used in FPV (Freeze Protection 

Valve).

4. Tie the Heat Trace cable to the FPV with Cable ties or

Fiberglass tape. (See Detail)

5. Insulate FPV with foam insulation. (Supplied by Others)

Manual #7109-208-001

Page 5 of 11

Revised: 11/12/18

 

Acorn Safety

 

a division of Acorn Engineering Company™

EXISTING SUPPLY

SUPPLIED HEAT

TRACE CABLE

MOUNTING BOLTS

& HARDWARE TYPICAL

4X (PROVIDED BY

INSTALLER)

A

C

B

MOUNTING SCREWS

& HARDWARE TYPICAL
2X (PROVIDED BY

INSTALLER)

INSPECTION TAG
LOCATION

FPV DETAIL
LOCATED ON
NEXT PAGE

Содержание S1360-HT

Страница 1: ...ued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job sites during constru...

Страница 2: ...ve unwanted debris from the lines and prevent unwanted blockages in the safety equipment 5 All employees at risk of contamination should be informed and trained in the use of this and any other safety...

Страница 3: ...n Safety a division of Acorn Engineering Company Installation Operation Manual SHOWER SPRAY PATTERN 20 508 SPRAY PATTERN 34 435 8 32 821 CLEAR ZONE GENERAL NOTES 1 ALL DIIMENSIONS ARE IN INCHES MM 2 A...

Страница 4: ...d Combination Station Eye Face Wash Plastic Showerhead Drench Hose S1360 HT 84 7 16 645 8 42 235 8 883 8 93 4 8 FREEZE PROTECTION VALVE INSTALL OPPOSITE SUPPLY 1 1 4 NPT OPTIONAL SUPPLY LOCATION GENER...

Страница 5: ...ns STEP TWO SUPPLY AND SANITARY DRAIN CONNECTION 2 Make sure proper drainage is supplied nearby 1 Install necessary pipe fittings supplied by others to make connection to 1 NPT supply union w potable...

Страница 6: ...rn Engineering Company Installation Operation Manual DETAIL VIEW EXPLODED VIEW FPV CABLE TIES OR FIBERGLASS TAPE BY OTHERS 1 2 NPT X 1 2 ID TUBE BARBED 1 2 14 ANTI FREEZE VALVE 1 2 14 X 1 1 2 L Galv N...

Страница 7: ...OPEN AND BLEED WATER UNTIL THE VALVE TEMPERATURE INCREASES THIS CAN BE REMEDIED BY SUPPLYING TEMPERED WATER TO THIS UNIT MAKE SURE THAT HEAT TRACE CABLE HAS HAD TIME TO WARM UP BEFORE TESTING WITH COL...

Страница 8: ...The route and area surrounding the Drench Shower should be clear and unobstructed the sooner a person has rinsed off any contamination the less likelihood of injury Drench Shower stations should be lo...

Страница 9: ...obstructed the sooner eyes are flushed the less likelihood of damage Eye Wash stations should be located in close proximity to the hazard and take no more than 10 seconds to reach In the case of sever...

Страница 10: ...ation Operation Manual Manual 7109 208 001 Revised 11 12 18 Page 10 of 11 Acorn Safety a division of Acorn Engineering Company 1 2 3 4 5 6 7 8 9 10 29 28 27 26 23 22 21 9 20 19 18 17 16 15 14 13 12 25...

Страница 11: ...008 000 3 8 16 ZINC PLATED NUT 14 7100 400 000 PUSH HANDLE LABEL 15 7106 407 199 ACTIVATOR PUSH HANDLE HT TRACE 16 7100 325 000 S S 1 1 4 x1 2 NPT REDUCING BUSHING 17 1974 001 000 1 2 14x1 5 L GALV NP...

Отзывы: