The picture shows 240VAC arrangement.
Now find the LV transformer voltage selector on the Mains PCB and arrange the
jumpers there according to the selected table row.
Connect all five connectors you disconnected in the beginning plus two new
connectors from HV transformer.
Replace the cover, reinstall all nine M3x6 screws first loosely, and finally tighten
them properly.
C A U T I O N
If the amplifier is wired for 100-120VAC, do not forget to replace
the two rear panel fuses.