7
Z-weighted peak sound pressure level (L
peak
) measurment
The peak sound pressure level is peak sound pressure level of the sound wave before
smoothed with the time weighting characteristics.
L
peak
is wavy peak level of Z characteristic.
<
Parameter setting
>
Measurement is made according to the following procedure.
①
Frequency weighting key
:
Z
②
Display mode key
:
Peak
③
Time weighting key
:
F, S or Imp
④
Range key
:
Select a range where the bar graph indicates
approximately 2/3 of the full scale.
【
Method of selecting [Range] key
】
Press [Range] key, and choose by cursor keys
▲▼
, and press [Range] key
again to register.
⑤
Measuring time key
:
1s, 3s, 5s, 10s
,
1m
,
5m
,
10m
,
15m, 30m
,
1h, 8h, 24h
and
***
(input to the [Start/Stop] key)
The measurement starts with [Start/Stop] key.
<
Display
>
Measuring
time
Rec:Blinks during
recording
Stp: Holding state
1s 000h00m00s
63.5 dB
40
130
Stp Z
Fast Peak
Display mode
Peak
Time weighting
:
Fast, Slow or Imp
Frequency weighting : Z
②
Display
mode key
④
[Range] key
③
Time weighting
key
(F:Fast, S:Slow,
Imp: Impulse)
①
Frequency
weighting key
(A
・
C, Z)
⑤
Measuring
time key
Содержание 6236
Страница 1: ...Sound Level Meter TYPE 6236 Instruction Manual ACO Co Ltd...
Страница 53: ...52 Appearance diagram of Sound Level Meter TYPE 6236...
Страница 72: ...Sound Level Meter TYPE 6236 Instruction guide ACO Co Ltd...
Страница 92: ...Sound Level Meter TYPE 6236 Instruction Manual for Data Management Software NA 0038M ACO Co Ltd...
Страница 151: ...60 1 3 Octave Real time Analysis measurement data Logging Panel Normal Panel Extension Panel...