29
Time level display of Sound pressure level (L
A
/Lc/L
p
) measurement
<
Parameter setting
>:
The time level is displayed at each contiguous push (1.5s) of [Mode] key as follows, returning to
the standard display screen when the key is pushed again.
The key operation is similar to the measurement of sound pressure level (L
A
/Lc/Lp).
<
Display
>
The instantaneous level is displayed at each about 300ms from right to left.
Data hold
By pushing the [Pause] key, the blinking letter “Pause“ is displayed at the center of the bar
graph, displaying the present instantaneous level. Note that the bar graph itself doesn't pause.
<
Standard display
>
Pause
→→→
<
Time level display
>
・
By pushing the [Pause] key is pushed again, it is released.
Data
40
130
Pause
10m 000h00m05s
63.5 dB
Stp Z
Fast
Lp
20
80dB
Fast
Lp
38.6
dB
③
Frequency
weighting key
:
Fast, Slow or Imp
④
Display mode key
②
Instantaneous level
:
Per second display
①
Range
60
130dB
Fast
Lp
63.5
dB
Pause