background image

Tel. +49 (0) 36965 819–0

Fax +49 (0) 36965 819–361

2

Service-Line

Contents

1.  Notes on manual 

..................................................................................................................3

2.  Basic safety notes and warnings 

....................................................................................3

3. Product 

description

3.1 

Scope of supply  ............................................................................................................................. 4

3.2 Technical 

data 

................................................................................................................................ 4

3.3 Description 

.................................................................................................................................... 4

3.4 

Correct intended use ....................................................................................................................... 5

4. Assembly

4.1 

Disassembly of appliance ................................................................................................................. 5

4.2 

Preparations at grease separator...................................................................................................... 6

4.3 

Assembly of appliance in the grease separator ................................................................................... 6

5. Commissioning 

......................................................................................................................8

6. Operation

6.1 Function 

......................................................................................................................................... 9

6.2 

Description of front wall of evaluation device .................................................................................... 10

6.3 

Condition description: half level signal = 50 % of max. grease storage capacity ................................... 10

6.4 

Condition description: full  level signal = 80 % of max. grease storage capacity................................... 10

6.5 

Possible malfunctions  ................................................................................................................... 11

7. Servicing

 .................................................................................................................................11

8. Spare 

parts 

............................................................................................................................11

Содержание 3300.11.50

Страница 1: ...tion I n s t a l l a t i o n a n d o p e r a t i n g m a n u a l GREASE LEVEL CONTROL Measuring device for grease layer thickness Please read through this manual carefully and completely prior to comm...

Страница 2: ...4 1 Disassembly of appliance 5 4 2 Preparations at grease separator 6 4 3 Assembly of appliance in the grease separator 6 5 Commissioning 8 6 Operation 6 1 Function 9 6 2 Description of front wall of...

Страница 3: ...ituations which could cause faults during operation of the appliance in case of non observance of directions given The product may only be applied and operated in accordance with its intended use as d...

Страница 4: ...s are still flashing and when reaching 80 only 1 red LED is still lighting Emptying of the separator must be arranged Two relays with change over contact activate the aggregates signals The NC connect...

Страница 5: ...rent use of the device is not permitted 4 1 Disassembly of appliance Step 2 Remove evaluation device and gripper clamps from measuring stick Step 1 Loosen spigot nut of angle plug and remove from meas...

Страница 6: ...he grease separator With assembly opening Dismantle dummy plug with sealing and counter nut ACO grease separators are generally supplied with assembly opening for measuring device of grease layer thic...

Страница 7: ...3 In the case of separators with high pressure HP internal cleaning fig A sensors 1 point towards HP Orbital cleaning head 2 and with separators without HP internal cleaning fig B towards a maintenan...

Страница 8: ...must be carried out by an external fuse Observe operator protection Error current protective circuit Put the safety plug of the plug in evaluation device into the socket with earth contact mounted in...

Страница 9: ...pacity Fuse protection of the load circuit must be car ried out externally via a fuse if required max 5A NC connection 2A NO connection For switching of higher currents relevant switching elements hav...

Страница 10: ...r Evaluation at evaluation device Table C Half level signal 50 max grease storage cap Display Lights Sensors Water Grease off green red exists exists LED 4 LED 3 LED 2 LED 1 By pressing test button 1...

Страница 11: ...s should be in the same position Only in the case of very different distances of electrodes to the reference electrode or in the case of long connection lines it is reasonable to adjust sensitivity in...

Страница 12: ...feld Tel 49 0 36965 819 0 Fax 49 0 36965 819 361 www aco haustechnik de www aco com ACO H a u s t e c h n i k Installation and Operating Manual As per 03 2010 Origin German Manual Art no 3300 11 50 HT...

Отзывы: