                                                                                                                                      XP-700WZA 

 

 

12A

                 

 

 

Fig.4                                                                    Fig.5 

Explanation of fig.5: 

Base 40

°

C

 Present 

temperature of base CPU is 40

°

001

    Present start address 

Md.1 16Ch

 

Present channel mode is mode 1 (16 channels mode) 

Lamp 30

°

C

 

Present temperature of lamp is 30

°

 

Warning signal blinking direct resetting error 

 

6.2 Main Function   

Turn on the unit, press 

MENU

 button into menu mode, press 

UP

 and 

DOWN

 button until the 

required function is shown on the monitor. Select the function by 

ENTER

 button. Use 

UP

 

and 

DOWN

 button to choose the submenu, press the 

ENTER

 button to store and 

automatically return to the last menu. Press 

MENU

 button or let the unit idle one minute to 

exit menu mode.   

In the event of disconnecting with mains power, press 

UP

 button for one minute to enter 

into menu mode. Press MENU button or let the unit idle one minute to exit. 

The main functions are shown below

the grayed boxes are preset settings: 

Содержание XPerior 700WZA

Страница 1: ...XPeriorTM 700WZA Wash User Guide Please read these instructions carefully before use ...

Страница 2: ...1A ...

Страница 3: ...6 How To Set The Unit 11 6 1 Power On Display 11 6 2 Main Function 12 6 3 Home Position Adjustment 21 6 4 Error Information 23 7 Control By Universal DMX Controller 23 7 1 Connection 24 7 2 Channel Mode Setting 25 7 3 Address Setting 25 7 4 DMX 512 Configuration 25 7 5 Lighting Library Download 30 8 Update Software 30 9 Troubleshooting 30 10 Maintenance and Cleaning 32 ...

Страница 4: ...sure that no ventilation slots are blocked otherwise the unit will be overheated y Before operating ensure that the voltage and frequency of power supply matches the power requirements of the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y Maximum ambient temperature TA 40 Don t operate it when the temperature is higher y Don t connect the dev...

Страница 5: ... housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged y Do not open the unit as there are no user serviceable parts inside y Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed y Disconnect the mains power if the fixture is ...

Страница 6: ...lders 2 on the bottom of the base by inserting quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Hang the fixture to the support 4 through clamp and fasten the screws 5 Fasten the safety cable 6 through the bottom of the base and over the support Fig 1 Fig 2 Attention y Always ensure that the structure to which you are attaching the unit is secure and is able to suppo...

Страница 7: ... 700 2 FastFit Battery backup display Setting DMX address or other functions without connecting to mains power Battery for LCD display charges automatically when the fixtures connects to the mains power No need to change battery Wireless control for the unit with wireless receiver built in only Wirelessly controlled by W DMX option Each W DMX is sending out 512 channels of DMX License free band of...

Страница 8: ...ffect Color wheel Color wheel1 7 dichroic colors open Color wheel2 7 dichroic colors open Rainbow effect in both directions Easy calibration and maintenance by magnetic home positioning CMY CMY speed adjustable Optional multiple preset colors and macros available Zoom Motorized linear zoom for smooth adjustment of beam size and beam sharpness Cool Fan cooled Protocols DMX 512 Date input output 3 5...

Страница 9: ... 7 Dimmer Color 1 Pan Tilt Macro 8 Color 1 Color 2 Pan Tilt Macro Speed 9 Color 2 Zoom Color 1 10 Cyan Preset Color Color 2 11 Magenta Color Macro 1 Cyan 12 Yellow Color Macro 2 Magenta 13 3200K CTO CMY CTO Speed Yellow 14 Preset Color Pan Tilt Macro 3200K CTO 15 Zoom Pan Tilt Macro Speed Preset Color 16 Function Pan CMY CTO Speed 17 Pan Fine Color Macro 18 Tilt Zoom 19 Tilt Fine Shutter 20 Pan Ti...

Страница 10: ...e head press the tilt unlock button 5 and move the pan lock unlock lever 6 to unlock position Caution The head and arm must be unlocked before operation 4 2 Control Panel Front View Rear View 1 Monitor Batter Back up display 2 LED POWER On Power on DMX On DMX input present 1 Arm 2 Front panel 3 head 4 Tilt lock button Black 5 Tilt unlock button Gray 6 Pan lock 7 Handle 8 Base 9 Antenna for XP 700W...

Страница 11: ...00 2 FastFit y Because of its high internal pressure there might be a risk that the Discharge lamp would explode during operation The lamp emits intense UV radiation which is harmful to the eyes and skin The high luminance of the arc can cause severe damage to the retina if you take a close look at the lamp y To protect the lamp always turn off the lamp first via control panel or DMX controller an...

Страница 12: ...oove turn it clockwise to fix the lamp 5 Tighten the screws A to fix the lamp cover 6 Turn the screws B to adjust the lamp position be sure it is located in the center of the reflector for the best projection 6 How To Set The Unit 6 1 Power On Display Every time you turn on the unit it will run built in program to reset all motors to their home position the display will show as fig 4 you may hear ...

Страница 13: ... mode press UP and DOWN button until the required function is shown on the monitor Select the function by ENTER button Use UP and DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press MENU button or let the unit idle one minute to exit menu mode In the event of disconnecting with mains power press UP button for one minute to enter into me...

Страница 14: ...XP 700WZA 13A ...

Страница 15: ... DMX Value or WDMX Setting DMX Address DMX512 address setting Select DMX Address press ENTER button to confirm the present address will blink on the display use jog wheel to adjust the address from 0 to 512 press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode DMX Channel Mode channel mode ...

Страница 16: ...on back to the last menu or let the unit idle one minute to exit menu mode Active Select Active press ENTER button to confirm use Jog wheel to select Yes wireless control available or No wireless control unavailable press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Set wireless control to be available the power indicate LED will s...

Страница 17: ...ore Press MENU button back to the last menu or let the unit idle one minute to exit menu mode BL O Color Change Blackout while change color Select BL O Color Change press ENTER button to confirm present mode will blink on the display use jog wheel to select No normal while changing color or Yes blackout while changing color press ENTER button to store Press MENU button back to the last menu or let...

Страница 18: ...irm present mode will blink on the display use UP and DOWN button to select Yes Lamp turns on when DMX signal is detected or No keep the present state press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode If the lamp is off via DMX signal you can reconnect the DMX controller to make the lamp on Off If DMX Off Lamp turns off when DMX s...

Страница 19: ...nit Display Inverse Select Display Inverse press ENTER button to confirm present mode will blink on the display use jog wheel to select No normal display or Yes inverse display press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Backlight Auto Off Select Backlight Auto Off press ENTER button to confirm present mode will blink on the...

Страница 20: ...n use jog wheel to adjust the value press ENTER button to store the fixture will run as the channel value indicates Press MENU button back to the last menu or exit menu mode let the unit idle one minute All channels value will become 0 after exiting Manual Test menu Fixture Information Enter menu mode select Fixture Information press ENTER button to confirm use jog wheel to select Fixture Use Time...

Страница 21: ...ns or No press ENTER button to store Press MENU button to exit Shutter Reset Shutter Select Shutter press ENTER button to confirm use jog wheel to select Yes the unit will run built in program to reset shutter to its home positions or No press ENTER button to store Press MENU button to exit Zoom Reset Zoom Select Zoom press ENTER button to confirm use jog wheel to select Yes the unit will run buil...

Страница 22: ... Factory Setting press ENTER button to confirm the fixture will reset to factory settings and exit menu mode 6 3 Home Position Adjustment Press MENU button into menu mode then press ENTER button for about 3 seconds into offset mode to adjust the home position Select the function by ENTER button Use jog wheel to choose the submenu press the ENTER button to store and automatically return to the last...

Страница 23: ...n press ENTER button to confirm the present position will blink on the display use jog wheel to offset the value from 0 to 255 press ENTER button to store Press MENU button to exit Magenta Magenta home position adjust Enter offset mode Select Magenta press ENTER button to confirm the present position will blink on the display use jog wheel to offset the value from 0 to 255 press ENTER button to st...

Страница 24: ...n 105 the unit will run on a low power level Maintenance Fixture It appears when the maintenance remaining time becomes 0S please enter menu mode and reset the time Lamp On Over 700 Hour It appears when the lamp has been on over 700 hours please turn off the lamp Memory Initial Fail It appears when the memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P C or some wire...

Страница 25: ... damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 The end of ...

Страница 26: ...DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press ENTER button to confirm use jog wheel to select DMX Address press ENTER button to confirm the present address will blink on the display use jog wheel to adjust the address from 0 to 512 press ENTER button to store Press MENU button back to the last menu or let the unit...

Страница 27: ...XP 700WZA 26A 16 Channels Mode 1 ...

Страница 28: ...XP 700WZA 27A 21 Channels Mode 2 ...

Страница 29: ...XP 700WZA 28A 21 Channels Mode 3 ...

Страница 30: ...XP 700WZA 29A ...

Страница 31: ... stick as the install folder from the pull down list 4 With the memory stick now plugged into the Pearl choose the Sync Fixture option This option can be found on soft key E of the System USB Stick Options menu 5 Select the manufacturer and fixture to starting controlling 8 Update Software Download update file from our web site follow the user manual of IU 01 to update the fixture via IU 01 not in...

Страница 32: ... might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition D The lamp is cutting out intermittently 1 The lamp is not working well Check the mains voltage either too high or too low 2 Internal temperature may be too high Check if replacement of fan is needed on the head E If The pan belt is broken 1 Turn off the mains power 2 Loosen th...

Страница 33: ... that all the screws and terminals have been locked firmly to make sure the normal performance of the fixtures Negligence of maintenance would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or...

Страница 34: ...XP 700WZA 33A ...

Страница 35: ...rk in accordance with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 1996 EN55103 2 1996 EN61000 3 2 2006 EN61000 3 3 2008 Harmonized Standard EN 60598 2 17 1989 A2 1991 EN60598 1 2008 A11 2009 Part 1 General requirements and test Following the provisions of the low voltage directive 2006 95 EC ...

Страница 36: ...Innovation Quality Performance ...

Отзывы: