XP-5R Beam
-
3
-
during its operation, and allow about 15 minutes for cooling the unit down before
replacing bulb or maintenance as it could be very hot.
y
Avoid any inflammable liquids, water or metal objects entering the unit. Once it
happens, cut off the mains power immediately.
y
Do not operate in dirty or dusty environment; do clean the fixture regularly.
y
Do not touch any wire during operation as there might be a hazard of electric shock.
y
Avoid power wires twist other cables.
y
The minimum distance between light output and the illuminated surface must be more
than 2.5 meters.
y
Disconnect mains power before fuse/lamp replacement or servicing.
y
Replace fuse/lamp only with the same type.
y
In the event of serious operating problem, stop using the unit immediately.
y
Never turn on and off the unit time after time.
y
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
y
Do not open the unit as there are no user serviceable parts inside.
y
Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead
to damage or malfunction. Please contact the nearest authorized technical assistance
center if needed.
y
Disconnect the mains power if the fixture is has not been used for a long time.
y
Do use the original packing materials before transporting it once again.
y
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
y
Hot lamp explosion hazard. Do not open the unit within 15 minutes after switching off.
y
Do replace the bulb once it is damaged, deformed or life-expired.
y
Do not look directly at the light while the bulb is on.
y
Never touch bulb with bare fingers, as it is very hot after using.
y
Do not start on the unit without bulb enclosure or when housing is damaged.
36-
9. Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED to see if it can be light up or not.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if they are linked
properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
4. Try to use another DMX controller.
5. Check to see if the DMX cables run near or run alongside high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal temperature may be too high. Check if replacement of fan is needed on the
head.
E. If The pan belt is broken
1. Turn off the mains power.
2. Loosen the screws (A)
,
open the cover (B).
www.bluelight.at