XP-5R Beam
-
27
-
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not
used.
7.2 Channel Mode Setting
Enter menu mode, select
DMX Functions
, press ENTER button to confirm, use UP and
DOWN button to select
DMX Channel Mode
, press ENTER button to confirm, present
channel mode will blink on the display, use UP and DOWN button to select
Mode1 (19
channels mode)
or
Mode 2 (16 channels mode) or Mode 3 (20 channels mode)
, press
ENTER button to store. Press MENU button back to the last menu or let the unit idle one
minute to exit menu mode.
7.3 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address
from 1 to 512 so that the units can receive DMX signal.
Press MENU button to enter menu mode, select
DMX Functions
, press ENTER button to
confirm, use UP and DOWN button to select
DMX Address
, press ENTER button to
confirm, the present address will blink on the display, use UP and DOWN button to adjust
the address from 0 to 512, press ENTER button to store. Press MENU button back to the
last menu or let the unit idle one minute to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
19 channels
1
20
39
58
16 channels
1
17
33
49
20 channels
1
21
41
61
12-
6. How To Set The Unit
6.1 Power On Display
Every time you turn on the unit, it will run built-in program to reset all motors to their home
position, the display will show as fig.4, you may hear some noises for about 20 seconds. It
will show warning sign if it goes wrong during resetting and you can press the MENU button
to view the error information. After that the unit will be ready to receive DMX signal and the
display will show as fig.5.
Fig.4 Fig.5
Explanation of fig.5:
Base 40
°
C
Show temperature of base CPU is 40
°
C
001
Show start address
Md.3 20.
Show channel mode is mode 3 (20hannels mode)
Temp 30
°
C
Show temperature of lamp is 30
°
C
Warning signal blinking direct resetting error
6.2 Main Function
Turn on the unit, press
MENU
button into menu mode, press
UP
and
DOWN
button until the
required function is shown on the monitor. Select the function by
ENTER
button. Use
UP
and
DOWN
button to choose the submenu, press the
ENTER
button to store and
automatically return to the last menu. Press
MENU
button or let the unit idle one minute to
exit menu mode.
In the event of disconnecting with mains power, press
UP
button for one minute to enter
into menu mode. Press MENU button or let the unit idle one minute to exit.
The main functions are shown below
(
the grayed boxes are preset settings
)
:
www.bluelight.at
www.bluelight.at