ACME XP-1200F Скачать руководство пользователя страница 9

 

XP-1200F 

11- 

  Lamp ON/OFF 

Press the 

MENU

 button until the 

  is blinking on the display. Pressing 

ENTER

 button 

and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (Lamp on) or 

 (Lamp off) mode. Once the mode has been selected, press the 

ENTER

 button to 

setup or automatically return to the main functions without any change after 8 seconds. To 

go back to the functions without any change press the

 MENU

 button again. 

  Reset

 

Press the 

MENU

 button until the 

  is blinking on the display. Pressing 

ENTER

 button 

and all channels of the unit will return to their standard position. To go back to the functions 

press the

 MENU

 button again. 

 

  6.2 Home Position Adjust   

Press 

MENU 

button for at least 5 seconds into offset mode to adjust the home position, 

when you want to adjust gobo and color home position, you should be run 

 

mode 

first ,

 

the functions are shown below: 

 

Effect offset (-127~127)

Color offset (-127~127)

MENU

Dimmer offset (-127~127)

 

  Color offset  

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display 

will blink. Use 

DOWN

 and 

UP

 button to adjust the color home position. Once the color has 

been selected, press the 

ENTER

 button to setup or automatically return to the offset 

functions without any change press the 

MENU

 button again, To go back to the main 

functions without any change after 8 seconds. 

 Effect offset    

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display will 

 

XP-1200F 

                                                                                                                                                                                                         

8- 

5. Lamp   

MSI 1200W/S / HMI 1200/S K SFc10-4

 

y

  Because of its high internal pressure, there might be a risk that the Discharge 

lamp would explode during operation. The lamp emits intense UV radiation which 

is harmful to the eyes and skin. The high luminance of the arc can cause severe 

damage to the retina if looks directly at the lamp. 

y

  To protect the lamp, always turn off the lamp first (via control panel or DMX 

controller) and let the unit run at least five minutes before switching off the mains 

supply, never handle the lamp or luminaire when it is hot. 

y

  Do not touch the bulb with bare hands. If this happens, clean the lamp with 

denatured alcohol and wipe it with a lint free cloth before installation. 

y

  The lamp generates UV radiation. Never operate the lamp without appropriate 

shielding. 

y

  When lighting up, the lamp operates at high pressure and there is a slight risk of arc 

tube rupture. The risk increases with age, temperature and improper handling of the 

lamp. Do not use the lamp longer than its lifespan. 

y

  Make sure the lamp is located in the center of the reflector for the best projection. 

 

Change Lamp   

 

WARNING 

 

1. Turn off the power. 

2. 

Turn the head in horizontal position. Hinge must be on the upper side of the head. Turn 

screws left and remove plastic cover. Loosen head screw and open the lamp cover

 

 

In case of replacement of the lamp or maintenance, do not open the 
fixture within 15 minutes until the unit cools down after switching off. 

Содержание XP-1200F

Страница 1: ...6 x 30 mm Glass T15A Lamp MSI 1200W S HMI 1200 S K SFc10 4 Dimension 1170 x 330 x 225 mm 405 x 360 x 35 mm Controller Weight 42 4 kg Innovation Quality Performance Professional Intelligent Follow Spo...

Страница 2: ...nce with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN 55103 1 1996 EN 55103 2 1996 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 2...

Страница 3: ...optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty su...

Страница 4: ...erature is higher than this y Don t connect the device to any dimmer pack y During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device...

Страница 5: ...must be more than 2 5 meters y Disconnect mains power before fuse lamp replacement or servicing y Replace fuse lamp only with the same type y In the event of serious operating problem stop using the...

Страница 6: ...FIXED COLOURS RAINBOW switch Turning the switch on the COLOR SCROLL position enable the rainbow function you can set different rainbow speed by pressing COLOUR buttons from slow to fast Turning the sw...

Страница 7: ...d 7 2 Dedicated Controller IF series has 6 channels for international protocol DMX512 It can finish all operations via dedicated controller without using other controllers When the power is switched o...

Страница 8: ...hout any change after 8 seconds Dimmer offset Press the MENU button for at least 5 seconds into offset mode use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the...

Страница 9: ...the MENU button for at least 5 seconds into offset mode use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the display will XP 1200F 8 5 Lamp MSI 1200W S HMI 1200...

Страница 10: ...eset DMX 512 Address Setting Press the MENU button until the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the add...

Отзывы: