9B 

Optically Linear         Square Law           Inverse-Square Law            S-Curve 

Mode 1(Optically Linear): The increase in light intensity appears to be linear as DMX value is increased. 

Mode 2(Square Law): Light intensity control is finer at low levels and coarser at high levels. 

Mode 3(Inverse Square Law): Light intensity control is coarser at low levels and finger at high levels. 

Mode 4(S-cure):

 

Light intensity control is finger at low levels and high levels and coarser at medium 

levels. 

Dimmer Speed 

Select the

 Dimmer Speed

, press the 

ENTER

 button. Use the 

DOWN

 and 

UP

 button to select Fast or   

Smooth. Once selected, press the 

ENTER

 button to setup or exit menu mode without any change after 8 

seconds. Back to the functions without any change press the 

MENU

 button again.

 

White Balance   

Select the 

White Balance

, press the 

ENTER

 button to confirm. It can be adjusted with the whole fixture, 

or it can be adjusted independently for each block.Use the

 UP

 and 

DOWN

 button to select 

Red/Green/Blu/White,

 press the

 ENTER

 button to store, then use the 

UP

 and 

DOWN

 button to adjust 

the value from (125~255), press the

 ENTER

 button to confirm. (DMX signal will be the first priority under 

Manual Mode.) Once selected, press the

 ENTER

 button to store. Press the 

MENU

 button back to the last 

menu without any change or idling 8 seconds to exit menu mode. 

 

Language

 

Select the 

Language

, press the 

ENTER

 button to confirm. Use the

 UP

 and 

DOWN

 button    to adjust 

English or Chinese .Once selected, press the

 ENTER

 button to store. Press the 

MENU

 button back to the 

last menu without any change or idling 8 seconds to exit menu mode. 

 

Содержание Thunderstruck LP-2304

Страница 1: ...LP 2304 ...

Страница 2: ...chnical Specifications 3 3 Installation and Connection 4 4 How to set the unit 5 4 1 Rear Panel 5 4 2 Main Function 6 5 How to control the unit 12 6 DMX512 configuration 13 7 DMX512 Connection 15 8 Troubleshooting 16 9 Fixture Cleaning 17 ...

Страница 3: ...ere are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service please contact your nearest dealer In the event of serious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Ple...

Страница 4: ... fixture to the support through clamp and faster the screws Faster the safety cable through the bottom of the base and over the support 2 Technical Specifications 13 channel Modes Ideal for discotheques clubs bars parties Mobile DJs etc Input Voltage AC100V 240V 50 60Hz Total Power consumption 1500W Power Cord Daisy Chain 1Fixtuer 120V 2 Fixtuer 220V Beam Angle 110 IP Grade IP 65 LED Sources 0 4W ...

Страница 5: ...aching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it The unit should be mounted in the height of 0 to 30m ...

Страница 6: ...5B 4 How to set the unit 4 1 Rear Panel 1 Display Show the various menus and the selected functions 2 Button MENU To select the programming functions ...

Страница 7: ... input DMX signal and to link the next unit 6 Ethernet in Ethernet Thru For ArtNet link 4 2 Main Function To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will return to the main functions without any change...

Страница 8: ...7B ...

Страница 9: ...the ENTER button Use the DOWN and UP button to select the Channel there are 13 channel Modes Once selected press the ENTER button to store Press the MENU button back to the last menu without any change or idling 1 minute to exit menu mode DMX Last State Select the DMX Last State press the ENTER button Use the DOWN and UP button to select Blackout or Hold Once selected press the ENTER button to sto...

Страница 10: ...he functions without any change press the MENU button again White Balance Select the White Balance press the ENTER button to confirm It can be adjusted with the whole fixture or it can be adjusted independently for each block Use the UP and DOWN button to select Red Green Blu White press the ENTER button to store then use the UP and DOWN button to adjust the value from 125 255 press the ENTER butt...

Страница 11: ... the ENTER button to confirm Display will show the temperature of the fixture Press the MENU button back to the last menu or idling 8 seconds to exit menu mode Fixture Hours Select Fixture Hours press the ENTER button to confirm Display will show the number of working hours of the unit Press the MENU button back to the last menu or idling 8 seconds to exit menu mode Software Version Select Softwar...

Страница 12: ...N THUNDERSTRUCK DMX PERSONALITY DMX 4 4Channel 8 bit DMX 8 8Channel 16 bit DMX 8 8 Channel DMX 52 52 Channel DMX12 1 Piexl DMX16 2V Piexl DMX16 2H Piexl DMX20 3 Piexl DMX24 4 Piexl DMX32 6V Piexl DMX32 6H Piexl DMX56 12 Piexl DEVICE LABEL THUNDERSTRUCK IDENTIFY DEVICE Off On DEVICE HOURS SOFTWARE RESET DEVICE Warm Cold ...

Страница 13: ...it 1 By DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once Turn on the unit under the DMX signal the LED will display the saved channel address 001 512 ...

Страница 14: ...13B 6 DMX512 configuration Channel Mode ...

Страница 15: ...14B ...

Страница 16: ...15B ...

Страница 17: ...o be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 5 pin XLR connectors 3 pin XLR Pin 1 GND Pin...

Страница 18: ...X cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s ...

Страница 19: ...18B ...

Страница 20: ...Innovation Quality Performance ...

Отзывы: