ACME Eventx 100 Скачать руководство пользователя страница 24

6 - DMX chart 
 

5 Channels Mode: 

 

Channel 

Value 

Function 

000-255 

RED      

  Dimmer 0% – 100% 

000-255 

GREEN   

  Dimmer 0% – 100% 

000-255 

BLUE     

  Dimmer 0% – 100% 

000-255 

WHITE   

  Dimmer 0% – 100% 

000-255 

ZOOM   

  0% – 100% 

 

7 Channels Mode: 

 

Channel 

Value 

Function 

000-255 

BEAM DIMMER   

  0% – 100% 

 
000-007 
008-015 
016-131 
132-139 
140-181 
182-189 
190-231 
232-239 
240-247 
248-255 

STROBE EFFECT 
Off 
On 
Strobe from slow to fast 
On 
Slow open fast close 
On 
Slow close fast open 
On 
Random strobe 
On 

000-255 

RED     

  Dimmer 0% – 100% 

000-255 

GREEN   

  Dimmer 0% – 100% 

000-255 

BLUE     

  Dimmer 0% – 100% 

000-255 

WHITE   

  Dimmer 0% – 100% 

000-255 

Zoom     

  0% – 100% 

 

 

23

A

 

 

Содержание Eventx 100

Страница 1: ...User Manual Please read the instructions carefully before use English Version 1 0...

Страница 2: ...n to the main 3 3 2 Mounting the fixture on a truss 4 3 3 DMX 512 connection 5 3 4 DMX 512 controller 6 3 5 IR remote control 6 3 6 Wireless connection 7 4 Description of EventX 100 9 4 1 Dimension 9...

Страница 3: ...es In the event of serious operating problem stop using the unit immediately Never turn on and off the unit time after time The housing the lenses or filter must be replaced if they are visibly damage...

Страница 4: ...ain must be approved for a safe working load of 10 times the weight of the fixture and it must have a minimum gauge of 2 mm Ensure that any supporting structure used can hold at least 10 times the wei...

Страница 5: ...e is out of the touch of people and has no one pass by or under it The fixture must never be fixed swinging freely in the room This fixture can be placed on the stage floor or rigged on a truss withou...

Страница 6: ...DMX and pin 3 DMX into a 5 pin XLR plug and plug it in the DMX output of the last unit Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit...

Страница 7: ...ce the address has been selected press and keep the ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later To go back to the functions without any change p...

Страница 8: ...r as our XP LR 512 RT Press Menu button 2 seconds if the display is locked else one impulsion on the Menu button is necessary to access to the main menu The display will show DMX Address Use the UP DO...

Страница 9: ...rm Use the UP DOWN button to select Yes or No Press the ENTER button to confirm The display will show Press up and down key Hold over 5s Do not press now You must first press the Function button of th...

Страница 10: ...uring this process the display will show Radio Code Clearing You can release Up and Down buttons when the display come back to the main menu WF will appear 4 Description of EventX 100 4 1 Dimensions 9...

Страница 11: ...the selected functions 6 Power Switch Press to turn on off the power 7 Power Charger Connect to the power adapter to charge 8 DMX In Water proof DMX socket input 9 DMX Out Water proof DMX socket outp...

Страница 12: ...ave2 S3 Slave3 3 Address DMX setting 001 to 512 4 EventX 100 connection DMX or WiFi 5 Display statue Lock 6 Charge level of the battery Main Menu without connection 1 Fixture M S setting Master Mode S...

Страница 13: ...nge the mode Once mode wished selected press the ENTER button to setup No action for one minute it will automatically return to the main Menu and the display will be locked Back to the last menu witho...

Страница 14: ...13A...

Страница 15: ...ess the ENTER button to confirm Use the UP DOWN button to select 5 Channel 7 Channel or 8 Channel Press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one m...

Страница 16: ...tures and the battery life will be shorter Max Power let you acces to White Balance menu Max Power selected Press the ENTER button to confirm Press the MENU button back to the last menu or let the uni...

Страница 17: ...u mode Show Program In this menu users are able to build a show Each program is constituted of one or more Acts which are themselves composed of one or more Scenes Press Menu button 2 seconds if the d...

Страница 18: ...the ENTER button to confirm Delete With this function users are able to delete one Act between Act 1 to Act 10 Delete selected Press the ENTER button to confirm Use the UP DOWN button to select betwee...

Страница 19: ...o select Clear all Scene 1 to Scene 20 Clear all With this function users are able to clear all data of all scenes Clear all selected Press the ENTER button to confirm Use the UP DOWN button to select...

Страница 20: ...of blue output 0 Black 255 100 Blue Blue selected Press the ENTER button to confirm Use the UP DOWN button to change the value 0 to 255 Press the ENTER button to confirm Press the MENU button back to...

Страница 21: ...e channel wished Press Menu button 2 seconds if the display is locked else one impulsion on the Menu button is necessary to access to the first menu Press Enter button the display will show DMX Settin...

Страница 22: ...elected Press the ENTER button to confirm Use the UP DOWN button to select English or Chinese Press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minut...

Страница 23: ...r Code Zoom Motor With this function users are able to reset the zoom motors Zoom Motor selected Press the ENTER button to confirm Use the UP DOWN button to select Yes or No Press the ENTER button to...

Страница 24: ...ls Mode Channel Value Function 1 000 255 BEAM DIMMER 0 100 2 000 007 008 015 016 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 STROBE EFFECT Off On Strobe from slow to fast On Slow open...

Страница 25: ...090 094 095 099 100 104 105 109 110 114 115 119 120 124 125 129 COLOR Open RGBW color mixing enabled LEE 790 Moroccan pink LEE 157 Pink LEE 332 Special rose pink LEE 328 Follies pink LEE 345 Fuchsia...

Страница 26: ...yellow LEE 104 Deep amber LEE 179 Chrome orange LEE 105 Orange LEE 021 Gold amber LEE 778 Millennium gold LEE 135 Deep golden amber LEE 164 Flame red White 2800K White 3200K White 4000K White 5600K W...

Страница 27: ...nd RGB DMX values The values R G B are approximate They were obtained by comparing the coordinates X Y from Lee table with a base white to 6000K These colors were obtained with EventX 100 is in calibr...

Страница 28: ...ow times 10 hours Display OLED display Data In Out 5 pins XLR socket Fastening system One Omega clamp Flight Case for 4 units with main power socket for battery charger Protection rating IP65 Physical...

Страница 29: ...ress settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the...

Страница 30: ...29A...

Страница 31: ...he provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2...

Страница 32: ...Innovation Quality Performance...

Отзывы: