ACME CB-16TC Скачать руководство пользователя страница 3

 17- 

The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6.  The end of the DMX 512 system should be terminated to reduce signal errors. 

7.  3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

          Pin 4/5: Not used. 

 

 

 

 

 

5. Troubleshooting   

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A.  The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

 

B.  Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

 

C.  Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling.   

2.  Check the LED for the response of the master/ slave mode signal. 

 

D.  No response to the sound 

 2- 

  1. Safety Instruction 

 

 

 

WARNING

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

  Unpack and check carefully there is no transportation damage before using the unit. 

y

  Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

 It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

 The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

  Disconnect main power before replacement or servicing.   

y

  Make sure there is no flammable materials close to the unit while operating as it is fire 

hazard.  

y

  Use safety cable when fixes this unit.   

y

  Maximum ambient temperature is TA: 40

. Don’t operate it where the temperature is 

higher than this. 

y

  In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or 

malfunction. Please contact the nearest authorized technical assistance center. Always 

use the same type spare parts. 

y

  Do not touch any wire during operation as high voltage might be causing electric shock. 

y

   

Warning 

 

 

 

 

 

 

 

Please read carefully the instruction, which includes important 

information about the installation, usage and maintenance. 

For power supply, if use the 230Vac 50Hz power supply, do not connect in 

series much more than 8 units, use another mains supply for next 8 units. 

If use the 120Vac 60Hz power supply, do not connect in series much more 

than 4 units, use another mains supply for next 4 units.

 

Содержание CB-16TC

Страница 1: ...sion of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements COLOR BAR 16TC CB 16TC User Guide Professional Entertainment Technology ...

Страница 2: ... is too low E One of the channels is not working well 1 The cable connected to the PCB may broken 6 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of di...

Страница 3: ...it to another user be sure that they also receive this instruction booklet y Unpack and check carefully there is no transportation damage before using the unit y Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y The unit is for indoor use o...

Страница 4: ...under Master Slave mode trigged by music z Individual control of each LED cluster z Sound sensitivity adjustable via the menu z Auto fading show with 5 different speeds z Specially designed stand for floor operation z LCD display for easy addressing and setting z Power Supply 120 230V 50 60Hz z Fuse T 6 3A z Power consumption 74W z LED 3W Tri color x 16pcs z Dimension 965 x 167 x 152 mm z Weight 6...

Страница 5: ...ct the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Microphone Receive the sound to control the unit Only for remote control By connect to the 1 4 microphone jack to control the unit for Stand by Function and Mode function Mains input Connect to supply mains power Mains output Connect to suppl...

Страница 6: ...OWN and UP button to change the mode Once the required mode has been selected Press ENTER button to store Back to the main functions without any change press the MENU button or wait for 8 seconds Hold MENU button to quit menu mode the unit will run the built in program you selected At this time you can press DOWN and UP button to change show the new show will effect immediately If you change to Au...

Страница 7: ...13 DMX Configuration 6 ...

Страница 8: ... UP button to select the 1 1MSL 3 4 5 6 12 24 48 50or LC 1 or LC 2 channels mode Once selected press the ENTER button to store Back to the main functions without any change press the MENU button or 12 4 3 DMX Controller Using universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the ...

Страница 9: ...Fade or Auto SO Chase press the ENTER button to confirm then you can press DOWN and UP button to select Speed1 to Speed 5 or Left Right Speed1 or Left Right Speed5 press ENTER button to store If you choose Sound Mode press the ENTER button to confirm then you can press DOWN and UP button to select Sound Random or Sound TC Chase or Sound SO Chase or Sound ST Chase or Sound MO Chase or Sound MT Chas...

Страница 10: ...u mode Auto Test Press the MENU button up to when the Auto Test is showing on the display Pressing ENTER button and the display will show Test and the unit will run self test by built in program To go back to the functions press the MENU button 10 White Balance Press the MENU button up to when the White Balance is showing on the display Press ENTER button and the r 255 will blink press UP and Down...

Отзывы: