 9- 

control on) or off (sound control off) mode. Once selected, press the 

ENTER

 button to store. 

Back to the main functions without any change press the

 MENU

 button (or wait for 8 

seconds to exit menu mode). 

 

Sound Sense 

Press the 

MENU

 button up to when the Sound Sense is showing on the display. Press 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to adjust the sound 

sensitively (1-100) of the unit. Once the value has been selected, press the 

ENTER

 button 

to store. Back to the main functions without any change press the

 MENU

 button (or wait for 

8 seconds to exit menu mode). 

 

Black Out   

Press the 

MENU

 button up to when the Black Out is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the yes (yes 

blackout) or no (no blackout) mode. Once selected, press the 

ENTER

 button to store. Back 

to the main functions without any change press the

 MENU

 button (or wait for 8 seconds to 

exit menu mode). 

 

Back Light 

Press the 

MENU

 button up to when the Back Light is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the on (back 

light on) or off (back light off 1 minute after auto show) mode. Once selected, press the 

ENTER

 button to store. Back to the main functions without any change press the

 MENU

 

button (or wait for 8 seconds to exit menu mode). 

 

Fixture Reverse   

Press the 

MENU

 button up to when the Fixture Reverse is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the yes or no . 

Once selected, press the 

ENTER

 button to store. Back to the main functions without any 

change press the

 MENU

 button (or wait for 8 seconds to exit menu mode). 

 

Auto Test 

Press the 

MENU

 button up to when the Auto Test is showing on the display. Pressing 

ENTER

 button and the display will show Test… and the unit will run self-test by built-in 

program. To go back to the functions press the

 MENU

 button. 

 

 10-

White Balance 

Press the 

MENU

 button up to when the White Balance is showing on the display. Press 

ENTER

 button and the r 255 will blink, press 

UP

 and 

Down

 button to adjust the value, press 

ENTER

 button to store and g 255 will blink on the display, press 

UP

 and 

Down

 button to 

adjust the value, press 

ENTER

 button to store and b 255 will blink on the display, press 

UP

 

and 

Down

 button to adjust the value, and press 

ENTER

 button to store. Back to the main 

functions without any change please press the

 MENU 

button. 

 

Fan Speed 

Press the 

MENU

 button up to when the Fan Speed is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN 

and 

UP

 button to select Auto Speed 

(When the temperature of the unit under 40

, FAN stops; between 45

~55

, FAN runs at 

half speed; above 60

, FAN runs at full speed. The LEDs 

will be off if the temperature 

higher than 75

) or High Speed, press ENTER button to store. To go back to the functions 

press the

 MENU

 button. 

 

Fixture Temp 

Press the 

MENU

 button up to when the Fixture Temp is blinking on the display. Pressing 

ENTER

 button and the display will show the temperature of the unit. To go back to the 

functions press the

 MENU

 button. 

 

Fixture Time 

Press the 

MENU

 button up to when the Fixture Time is blinking on the display. Pressing 

ENTER

 button and the display will show the number of working hours of the unit. To go back 

to the functions press the

 MENU

 button. 

 

Firmware Version 

Press the 

MENU

 button up to when the Firmware Version is blinking on the display. 

Pressing 

ENTER

 button and the display will show the version of software of the unit. To go 

back to the functions press the

 MENU

 button. 

 

 

 

 

 

 

Содержание CB-16TC

Страница 1: ...sion of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements COLOR BAR 16TC CB 16TC User Guide Professional Entertainment Technology ...

Страница 2: ... is too low E One of the channels is not working well 1 The cable connected to the PCB may broken 6 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of di...

Страница 3: ...it to another user be sure that they also receive this instruction booklet y Unpack and check carefully there is no transportation damage before using the unit y Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y The unit is for indoor use o...

Страница 4: ...under Master Slave mode trigged by music z Individual control of each LED cluster z Sound sensitivity adjustable via the menu z Auto fading show with 5 different speeds z Specially designed stand for floor operation z LCD display for easy addressing and setting z Power Supply 120 230V 50 60Hz z Fuse T 6 3A z Power consumption 74W z LED 3W Tri color x 16pcs z Dimension 965 x 167 x 152 mm z Weight 6...

Страница 5: ...ct the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Microphone Receive the sound to control the unit Only for remote control By connect to the 1 4 microphone jack to control the unit for Stand by Function and Mode function Mains input Connect to supply mains power Mains output Connect to suppl...

Страница 6: ...OWN and UP button to change the mode Once the required mode has been selected Press ENTER button to store Back to the main functions without any change press the MENU button or wait for 8 seconds Hold MENU button to quit menu mode the unit will run the built in program you selected At this time you can press DOWN and UP button to change show the new show will effect immediately If you change to Au...

Страница 7: ...13 DMX Configuration 6 ...

Страница 8: ... UP button to select the 1 1MSL 3 4 5 6 12 24 48 50or LC 1 or LC 2 channels mode Once selected press the ENTER button to store Back to the main functions without any change press the MENU button or 12 4 3 DMX Controller Using universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the ...

Страница 9: ...Fade or Auto SO Chase press the ENTER button to confirm then you can press DOWN and UP button to select Speed1 to Speed 5 or Left Right Speed1 or Left Right Speed5 press ENTER button to store If you choose Sound Mode press the ENTER button to confirm then you can press DOWN and UP button to select Sound Random or Sound TC Chase or Sound SO Chase or Sound ST Chase or Sound MO Chase or Sound MT Chas...

Страница 10: ...u mode Auto Test Press the MENU button up to when the Auto Test is showing on the display Pressing ENTER button and the display will show Test and the unit will run self test by built in program To go back to the functions press the MENU button 10 White Balance Press the MENU button up to when the White Balance is showing on the display Press ENTER button and the r 255 will blink press UP and Down...