background image

8A 

  7. DMX512 Configuration   

 

DMX512 configuration 

DMX512 

Level rang 0~255 

Channel 1 

Channel 2 

Strobe Speed 

Dimmer 

240~255 

Speed 15 

Dimmer 15 

224~239 

Speed 14 

Dimmer 14 

208~223 

Speed 13 

Dimmer 13 

192~207 

Speed 12 

Dimmer 12 

176~191 

Speed 11 

Dimmer 11 

160~175 

Speed 10 

Dimmer 10 

144~159 

Speed 9 

Dimmer 9 

128~143 

Speed 8 

Dimmer 8 

112~127 

Speed 7 

Dimmer 7 

96~111 

Speed 6 

Dimmer 6 

80~95 

Speed 5 

Dimmer 5 

64~79 

Speed 4 

Dimmer 4 

48~63 

Speed 3 

Dimmer 3 

32~47 

Speed 2 

Dimmer 2 

16~31 

Speed 1 

Dimmer 1 

0~15 

Stopped 

Blackout 

 

 

  8. DMX512 Connection   

 

Содержание BF-1500ND B

Страница 1: ...BF 1500ND B BF 750ND B BF 1500ND B BF 750ND B User Guide Professional Entertainment Technology ...

Страница 2: ... Specifications 4 General Functions 5 How To Change The Lamp 6 How To Control the Unit A By Master Slave Built In Preprogrammed Function B By Easy Controller C By universal DMX Controller 7 DMX512 Configuration 8 DMX512 Connection 9 Troubleshooting 10 Fixture Cleaning ...

Страница 3: ...has occurred during transportation It is very important to ground the yellow green conductor in order to meet safety regulations Do not connect the device to any dimmer pack The electrical work that is necessary for installation must be done by qualified personnel Be sure to locate the unit in a place with adequate ventilation at least 15 cm from the walls Be sure that no ventilation slots are blo...

Страница 4: ...y chain which can hold over 12 times weight of the unit when you fix the equipment The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of human and has no one pass by or sit down 3 Technical Specifications Lamp XENON 1500W XENON 750W Power AC 230V 50Hz AC 230V 50Hz 120V 60Hz Fuse Circuit breaker 20A Circuit breaker 15A Dimensions 452 x 147 5 x 116...

Страница 5: ...dip switch 1 ON this unit is in master mode assign dip switch 1 and 10 ON at the same time to adjust dimmer and strobe speed 7 DIMMER This knob used to adjust brightness of the units 8 SPEED This knob used to adjust the speed of Strobe 5 How To Change The Lamp Always switch off the main supply and never handle the lamp or luminaire when it is hot Do not touch the bulb with bare hands If this does ...

Страница 6: ...ass base cover 3 Loose the screws of the lamp wire from terminator 5 Connect the lamp wire to the terminator 6 Reverse the procedures from step 2 to step 1 4 Take out the old lamp and replace the new one to the fixture ...

Страница 7: ...its will run as same as the first master unit 2 4 Light show set the dipswitch as the diagram the first master unit will run the built in programmer and control the other slave units for 4 light show Chase pattern in 4 light show mode Pattern 1 1234 Full on Pattern 2 1 2 3 4 4 3 2 1 Pattern 3 1 2 3 4 4 3 2 1 Pattern 4 12 34 23 14 Pattern 5 1 12 123 1234 123 12 1 stop 4 43 432 4321 432 43 4 stop Pa...

Страница 8: ... pattern triggered by music AUTO status LED light blinking Press button Function briefly for speed selection hold on the Function button for brightness selection C By universal DMX controller If you use a universal DMX controller to control the units you have to set dip switches from 1 to 9 of the channel so that all the units will receive its DMX signal Please refer to the following diagram to kn...

Страница 9: ...4 208 223 Speed 13 Dimmer 13 192 207 Speed 12 Dimmer 12 176 191 Speed 11 Dimmer 11 160 175 Speed 10 Dimmer 10 144 159 Speed 9 Dimmer 9 128 143 Speed 8 Dimmer 8 112 127 Speed 7 Dimmer 7 96 111 Speed 6 Dimmer 6 80 95 Speed 5 Dimmer 5 64 79 Speed 4 Dimmer 4 48 63 Speed 3 Dimmer 3 32 47 Speed 2 Dimmer 2 16 31 Speed 1 Dimmer 1 0 15 Stopped Blackout 8 DMX512 Connection ...

Страница 10: ...en power is disconnected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pi...

Страница 11: ...ical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 day...

Страница 12: ...magnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 General requirements and test Following the provisions of the low voltage directive 73 23 EEC and 93 68 EEC Innovation Quality Performance ...

Отзывы: