background image

ACL 2000 FLAME FAIL IGNITION SYSTEM

1

Manufacturing Inc.

ACL

Features

• 

 Safe and reliable ignition/flame sensing

 Self-powered operation

Innovative, compact design

 Easy to install

 Aluminum/stainless steel construction resists

  corrosion.

 Economically priced

 CSA approved gas valve

 Pilot Ignitor Tube lengths from 12” to 72”

 Ambient operating temperature (-40C to 65C)

 Maximum fuel supply - 25 PSI

 Alarm control capabilities

Application

The ACL 2000 Flame Fail Ignition System provides safe and reliable 
ignition/flame recognition for all types of gas fired heating appliances 
including line heaters, reboilers, dehydrators, and treaters.  
Economically priced and easy to install, the ACL 2000 mounts into 
position through a 1” NPT collar, eliminating unnecessary welding 
and installation of expensive latching valves or cheaters.  Its 
innovative, compact design is self-powered and incorporates an 
adjustable pilot, CSA approved gas valve, high temperature 
thermocouple, and stainless steel pilot nozzle.  

Содержание 2000

Страница 1: ...2000 FLAME FAIL IGNITION SYSTEM WARNING ACL is not responsible for the misuse or incorrect application of this product This manual must be read in its entirety before installation of this system Installation must be performed by a qualified technician and must adhere to the standards set by the local regulatory authorities ACL 2000 FLAME FAIL IGNITION MANUAL ...

Страница 2: ...4 6 Manufacturing Inc ACL ACL 2000 FLAME FAIL IGNITION SYSTEM ...

Страница 3: ...m control capabilities Application The ACL 2000 Flame Fail Ignition System provides safe and reliable ignition flame recognition for all types of gas fired heating appliances including line heaters reboilers dehydrators and treaters Economically priced and easy to install the ACL 2000 mounts into position through a 1 NPT collar eliminating unnecessary welding and installation of expensive latching...

Страница 4: ...per positioning schedule 40 piping is recommended Pilot nozzle tip must not extend past the burner into the main flame A clean steady dry fuel gas supply 25 PSI max is required for reliable operation When only wet gas is available it is recommended that a coalescing filter be installed before the gas leaves the heated building or directly after the filter regulator Purge air and debris from lines ...

Страница 5: ...IGNITION SYSTEM ACL 2000 and ACL High Efficiency Burner installed on boil off tank ACL2000 Main Burner Temp Control Valve Safety Shutdown Valve Main Burner Regulator Supply Pilot Regulator Supply 20 25 psi Supply Output Manual Shut Off Valve Optional Low level Shutdown ...

Страница 6: ...10 15 20 25 30 Replacing Pilot Ignitor Tube 12 1 Remove cap screws 8 loosen housing set screw 10 and slide aluminum housing 1 Down the pilot ignitor tube 12 2 Disconnect lead wire from piezo button 4 and disconnect thermocouple from gas valve button 2 3 Disconnect the pilot line from pilot valve assembly 3 4 Slide pilot ignitor tube 12 through the aluminum housing 1 and replace with new pilot igni...

Страница 7: ..._____________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ __________________________________________________________...

Страница 8: ...product which is found to be defective in such workmanship or material will be repaired or replaced by Seller for a period of one year from purchase date Warranty of such items do not include shipping installation or set up Liability Statement ACL Manufacturing Inc Shall not be liable for any special indirect consequential or other damages of a like general nature including without limitation loss...

Отзывы: