background image

-6- 

 

 

CONNECTORS

 

 

RJ45 Ethernet connector 

The Ethernet port is auto-sensing and self-configuring (auto-MDI/MDIX) to 
allow connection to either a crossover or straight-through connector. If it 
proves necessary to change the Ethernet cable, the following table indicates 
the pinout of connector 

J4 

located on the PCB. 

 

Pin 

Signal name 

Color 

DA+ 

White Orange 

DA- 

Orange 

DB+ 

White Green 

DB- 

Green 

DC+ 

Blue 

DC- 

White Blue 

DD+ 

White Brown 

DD- 

Brown 

 

Power supply connector 9 V – 36 V       (J3) 

 

Pin 

Signal name 

Color 

The product handles power supply 

wires inversion. 

 

 2 

+ V 

Red 

- (GND) 

Black 

 

Antenna connectors 

 

3 x RP-SMA female connectors 
 

 

LEDs definition

 

 
10 status LEDs indicate:  

 

Group 

LED 

Color 

Description 

WLAN 

State 

Green 

Off:

 

the radio is disabled 

Blinking: 

the product is unassociated 

solid “

On

the product is associated 

Act 

Blue 

Flashing

 :  Radio Tx/Rx activity. 

Signal 

Strength 

Green 

In client mode: 
 

once connected, represents 
the 

power of the radio signal

 

received from the AP 

In AP mode: Always 

off

 

ETHER

NET 

Link/ 

Activity 

Green 

On: 

Link on LAN established 

Flashing

:  Tx/Rx activity 

10/100/ 

1000 

Green/ 

Yellow 

Yellow

:  

connected in 1000 BASE T 

Green

connected in 100 BASE Tx 

Off

connected in 10 BASE T 

ADMIN 

Diag 

Red/ 

Green 

Indication of the unit operational state : 

 

OFF

:

 

Power supply is off 

Red

:

  

Initialization during 40s after 
powering up, then goes Green 

Red for more than 2 minutes

 

Hardware failure. 

Green

:

  

Ready to use 

Blinking

 

Firmware in flash is not valid; 
please load new firmware with 
NDM 

Power 

Green 

On

Power supply is applied. 

 

 

RJ45 connector 

T568B 

Содержание WLn-xROAD

Страница 1: ...n PC avec un accès Ethernet Le logiciel Acksys NDM un navigateur IE ou compatible JAVA version 6 ou plus version interne 1 6 0 Copyright 2017 par ACKSYS Selon la loi du 11 mars 1957 tout ou partie du présent document ne pourra être reproduit sans le consentement préalable de ACKSYS Avertissement Ce document n est pas contractuel ACKSYS ne garantit en aucune façon le contenu du présent document et ...

Страница 2: ...z que le voyant Power s allume Le voyant Diag reste rouge environ 40 secondes jusqu au démarrage complet du produit Une fois opérationnel le voyant Diag devient vert 3 Connectez le câble Ethernet La prise RJ45 sortant du produit peut être connectée sur un prise RJ45 10 100 1000 de votre réseau local Vérifiez que le voyant Link Activity s allume Vous pouvez remplacer le câble fourni par un câble pl...

Страница 3: ...pouvez également sélectionner l interface Ethernet ou la partie Services afin de les configurer Voici les paramètres essentiels à personnaliser o Le pays après avoir enregistré ce paramètre les canaux sont affichés en fonction de la réglementation o Le mode de fonctionnement Point d accès Bridge Mesh o Les paramètres Wi Fi Mode 802 11 canaux prendre en compte la législation en vigueur dans votre p...

Страница 4: ... d un adaptateur sans fil Paramétrez la connexion sans fil du PC2 selon les paramètres d usine fixés dans le point d accès 802 11gn SSID acksys sans sécurité Méthode pour essayer le produit en rôle client Avec deux produits ACKSYS et un second ordinateur équipé d une prise LAN filaire Paramétrez les adresses IP des équipements comme indiqué ci dessus et configurez le produit connecté à PC2 pour le...

Страница 5: ... pas le produit ACKSYS NDM scanne seulement le réseau local Pour traverser un routeur utilisez la fonction fichier base de produits distants Vérifiez que la machine Java n est pas bloquée par le firewall du PC Comment restaurer les paramètres usine du produit Si le produit est accessible par l interface web d administration vous pouvez utiliser le navigateur pour restaurer la configuration Sinon o...

Страница 6: ...on état Groupe LED Couleur Description WLAN State Vert Eteint Carte radio désactivée Clignotant Produit non associé Allumé fixe Produit associé Act Bleu Clignotant Envoi Réception de données par radio Signal Strength Vert En mode client une fois connecté représente la puissance du signal radio reçu de l AP En mode point d accès Toujours éteint ETHER NET Link Activity Vert Allumé Liaison Ethernet é...

Страница 7: ... 7 SPECIFICATIONS Longueur en diagonale entre les 2 trous de fixations 184 5mm Toutes les dimensions sont en mm ...

Страница 8: ... de passe et https Mise à jour du Firmware Par navigateur web ou par Acksys NDM Mode de fonctionnement AP Point d accès Bridge Client Mesh Répéteur WDS Pour le mode AP uniquement Topologie réseau Mode infrastructure ad hoc ou mesh Sécurité WEP WPA PSK WPA2 PSK WPA WPA2 avec authentification 802 1x SSID caché ou visible Pour le mode Client Bridge uniquement Topologie réseau Mode infrastructure ou a...

Страница 9: ... 22 dBm MCS 0 19 dBm MCS 7 22 dBm MCS 8 19 dBm MCS 15 22 dBm MCS 16 18 dBm MCS 23 802 11n HT20 bande a h 5GHz 18 dBm MCS 0 13 dBm MCS 7 18 dBm MCS 8 13 dBm MCS 15 18 dBm MCS 16 12 dBm MCS 23 23 dBm MCS 0 18 dBm MCS 7 23 dBm MCS 8 18 dBm MCS 15 23 dBm MCS 16 17 dBm MCS 23 802 11n HT40 bande a h 5GHz 17 dBm MCS 0 12 dBm MCS 7 17 dBm MCS 8 12 dBm MCS 15 17 dBm MCS 16 11 dBm MCS 23 22 dBm MCS 0 17 dBm...

Страница 10: ... de l information Sécurité EN 62311 Exposition humaine aux champs électromagnétiques EN 301 489 1 CEM et spectre radioélectrique ERM Norme de compatibilité électromagnétique pour les équipements et les services radio Partie 1 Exigences techniques EN 301 489 17 Partie 17 Conditions spécifiques pour les systèmes de transmission de 2 4 GHz en large bande et les équipements HiperLAN de 5 GHz EN 300 32...

Страница 11: ...Acksys NDM software a web browser IE or compatible JAVA version 6 or greater internal version 1 6 0 Copyright 2017 by ACKSYS Under the law of march 11 1957 the reproduction in whole or in part of this work by any means whatsoever is prohibited without the prior written consent of ACKSYS Disclaimer This document does not constitute a contract ACKSYS does not guarantee its contents in any way and ac...

Страница 12: ...ck that the Power LED turns on The Diag LED stays red for around 40 seconds until the device is fully ready to use Then the Diag LED turns green 3 Connect the Ethernet cable The RJ45 from the product can be connected to any RJ45 10 100 1000 plug of your local network Check that the Link Activity LED turns ON at that point You can replace the provided cable with a longer cable if you need to SOFTWA...

Страница 13: ...dio interface to set up its Wi Fi parameters you can also change IP configuration and services Set the following essential parameters o Country after applying this parameter channel regulation rules are enforced o The operating mode Access point client bridge mesh o Wi Fi parameters 802 11 mode radio channel take care about local legislation SSID o Wi Fi security parameters WEP WPA WPA PSK WPA2 WP...

Страница 14: ...e PC2 Wireless network interface according to the default parameters of the ACKSYS AP device 802 11gn SSID acksys no security Quickly evaluate the ACKSYS device in client role You need two ACKSYS devices and a second computer PC2 with a wired LAN connection Set up the IP addresses according to the picture above and set the device connected to PC2 to Client infrastructure role From each PC start a ...

Страница 15: ...ACKSYS NDM only scans the local network To reach a device through a gateway use the file remote products database function Check that your firewall does not block the Java machine How to restore factory settings If the built in web based interface is reachable you can use your browser to restore factory settings Else open the product see RESET below power up the unit wait for the red Diag LED to t...

Страница 16: ...oup LED Color Description WLAN State Green Off the radio is disabled Blinking the product is unassociated solid On the product is associated Act Blue Flashing Radio Tx Rx activity Signal Strength Green In client mode once connected represents the power of the radio signal received from the AP In AP mode Always off ETHER NET Link Activity Green On Link on LAN established Flashing Tx Rx activity 10 ...

Страница 17: ... 7 SPECIFICATIONS Diagonal length between hole centers 184 5mm All dimensions are given in mm ...

Страница 18: ...m any web browser username password protection https Firmware upgrade Yes via web browser or Acksys NDM Operating modes AP Access Point Repeater Bridge Client Mesh WDS AP mode only Network topology Infrastructure ad hoc or mesh Security WEP WPA PSK WPA2 PSK WPA WPA2 with 802 1x authenticator SSID visibility status Client Bridge mode only Network topology infrastructure mode ad hoc mode Security WE...

Страница 19: ...dBm MCS 16 13 dBm MCS 23 22 dBm MCS 0 19 dBm MCS 7 22 dBm MCS 8 19 dBm MCS 15 22 dBm MCS 16 18 dBm MCS 23 802 11n HT20 5 GHz a h band 18 dBm MCS 0 13 dBm MCS 7 18 dBm MCS 8 13 dBm MCS 15 18 dBm MCS 16 12 dBm MCS 23 23 dBm MCS 0 18 dBm MCS 7 23 dBm MCS 8 18 dBm MCS 15 23 dBm MCS 16 17 dBm MCS 23 802 11n HT40 5 GHz a h band 17 dBm MCS 0 12 dBm MCS 7 17 dBm MCS 8 12 dBm MCS 15 17 dBm MCS 16 11 dBm MC...

Страница 20: ...1 Information Technology Equipment Safety EN 62311 Human exposure to Electromagnetic Fields EMF EN 301 489 1 Electromagnetic compatibility and Radio spectrum Matters ERM Electromagnetic Compatibility EMC standard for radio equipment and services Part 1 Common requirement EN 301 489 17 Part 17 Specific conditions for 2 4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment EN...

Отзывы: