Functions description
15
ADIP
Installation Guide
System
description
Installation
parameters
Events
Accessories
Configuration
and cabling
Tables
Data
Compatible
elements
Functions
description
Delete
Supervision
Output Functions
Explanation
Output of a
configurable input
Activates when activating the corresponding input (
on this ac-
cess point and on another as well
). The relay can operate in
timed mode, Start / Stop or follower of the input
Access denied by
anti-
passback
Activates when a user denies access because of the antipass-
back. The relay can operate in time-delay mode or on / off
Access denied by
un-
known user
Activates when a user denies access because he is non-regis-
tered on the system. The relay can operate in time-delay mode
or on / off
Access denied by
number of consecu-
tive errors exceeded
Activates during 8 consecutive denied accesses. The relay can
operate in timed mode or Start / Stop mode
Access denied by
an-
other reason
Activates when a user denies access by a different cause than
the previous two. The relay can operate in time-delay mode
or on / off
Authorized access
Activates when the access is authorized for a user. The relay
can operate in timed mode or Start / Stop mode
Authorized access
group 25
Activates with an authorized access of an user of group 25.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 26
Activates with an authorized access of an user of group 26.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 27
Activates with an authorized access of an user of group 27.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 28
Activates with an authorized access of an user of group 28.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 29
Activates with an authorized access of an user of group 29.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 30
Activates with an authorized access of an user of group 30.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 31
Activates with an authorized access of an user of group 31.
The relay can operate in timed mode or Start / Stop mode
Authorized access
group 32
Activates with an authorized access of an user of group 32.
The relay can operate in timed mode or Start / Stop mode
Area 1
occupied
Activates when one or more users are within security zone 1.
Otherwise, it turns off
Area 1
saturated
Activates when the security area 1 has reached its capacity
limit. Otherwise, it turns off
Group counter 01
oc-
cupied
Activates when one or more users, belonging to group 1, are
within the security zone 1. Otherwise, it turns off
Group counter 01
saturated
Activates when the number of users belonging to group 1,
within security zone 1, has reached the limit of its counter.
Otherwise, it turns off
Group counter 02
oc-
cupied
Activates when one or more users, belonging to group 2, are
within the security zone 1. Otherwise, it turns off
Next page...