Functions description
14
ADIP
Installation Guide
System
description
Installation
parameters
Events
Accessories
Supervision
Configuration
and cabling
Tables
Data
Compatible
elements
Functions
description
Delete
Input Functions
Explanation
PB push-button opening door 1
The PB input - C
is dedicated to the door con-
trol 1 by pushbutton normally open at rest
PB push-button opening door 2
The PB input
- C
is dedicated to the door con-
trol 2 by pushbutton normally open at rest
G door burglary 1 and maximum
opening time
The input G - C
is dedicated to the supervi-
sion of the door 1 by magnetic contact nor-
mally closed
G door burglary 2 and maximum
opening time
The input G - C
is dedicated to the supervi-
sion of the door 2 by magnetic contact nor-
mally closed
Inhibition reader door 1
The input I - C
is dedicated to read enable
by sensor normally open when it is not use.
Can be read by door reader 1 when the sensor
switches to the closed state
Inhibition reader door 2
The input I - C
is dedicated to read enable
by sensor normally open when it is not use.
Can be read by door reader 2 when the sensor
switches to the closed state
Unlock Antipassback
Entry for automatic unlocking of all users
Inhibition
Input I (Inhibition) disables operation of the reader when it is closed. When this input
opens, the drive will resume operation. This serves, for example, to connect a buried
magnetic loop, so that the reader operates only when there is a present vehicle.
This input also allows to realize a SAS with two doors, equipped with an input reader
and an output pushbutton, without SAS time.
Output Functions
Output Functions
Explanation
Door lock 1 associated
with input
PB-1
The relay is dedicated to the door control 1, on identification
by
reader 1
. The relay can operate in timed mode
Door lock 1 associated
with input
PB-2
The relay is dedicated to the door control 1, on identification
by
reader 2
. The relay can operate in timed mode
Door lock 1 In / Out
associated with input
PB-1
The relay is dedicated to the door 1 control on identification
by drives 1 or 2. The relay can operate in time delay mode
Fraud gate 1 associ-
ated with input
G-1
Activates if door 1 is opened without the door lock output 1
being activated. Wire a door sensor between
G-1
and
C
Fraud gate 1 associ-
ated with input
G-2
Activates if door 2 is opened without the door lock output 2
being activated. Wire a door sensor between
G-2
and
C
Maximum time for the
opening of the gate
1 associated to input
G-1
Activates when door 1 is opened too long. The relay can op-
erate in timed mode. Wire a door sensor between G-1 and C.
Indicate the time of the function in seconds, from 0001 to
2400 for this max opening time
Output Functions
Explanation
Maximum time for the
opening of the gate
2 associated to input
G-2
Activates when door 2 is opened too long. The relay can op-
erate in timed mode. Wire a door sensor between G-2 and C.
Indicate the time of the function in seconds, from 0001 to
2400 for this max opening time
Input Functions