S.N.
Item
Functions
Parameters setting key
(Up key) Increase value
①
(Down key) Decrease value
Selects the program pattern number
Starts/hold the program, changes the mode from fixed value
control to program control
Program parameters setup
②
Changes the indication on SV/MV/TIME display
③
OUNT
Output indicator
④
STEP
Indicates the step number of program
⑤
PRO
(Program monitor indicator)
During program control, ‘
/
’ is lit when the PV is rising
During program control, ‘
-
’ is lit when the PV is constant
During program control, ‘
\
’ is lit when the PV is falling
⑥
PTN
(Pattern number display)
Indicates the pattern number ‘0
~
9’
⑦
RUN
(Program control runing indicator)
The LED indicator is lit during program control
⑧
PV
(PV Display)
Indicates the Process/Measured value
⑨
SV
It is lit when the Setting Value(SV) is being displayed on the
lower display
深圳利洋焊接设备
Shenzhen LiYang welding Equipment Co., Ltd
LY
The sixteen segments are defined in the order: Ramp 1, Dwell period 1, Ramp 2, Dwell
period 2..., and are executed in succession.
WWW.LYBGA.COM