background image

Hot Air SMD Rework Station

PRIOR TO USE

• 

Before operation select the appropriate FP pick-up wire that matches the size of 

the IC.

• 

The FP pick-up has an S wire (14mm) attached to it, while an L wire (30mm) may 

also be needed, depending on the size of the IC.

• 

Select the appropriate nozzle that matches the size of the IC.

• 

Loosen the screw on the nozzle.

• 

Insert the nozzle into the top.

• 

Fasten the screws properly.

IMPORTANT SAFETY INFORMATION

• 

When using electrical appliances basic safety precautions should always be 

followed.

• 

Check that the voltage indicated on the rating plate corresponds with that of the 

local network before connecting the appliance to the mains power supply.

• 

This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, 

unless they have been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety.

• 

Children shall not play with the appliance. Cleaning and user maintenance shall 

not be made by children unless they are older than 8 and supervised.

• 

Warning: The soldering iron must be placed on its stand when not in use.

• 

Do not leave the station unattended while it is switched on.

• 

Do not use in an explosive atmosphere or around flammable materials.

• 

Do not expose to rain or moisture.

• 

Never place the product or part of it in water, or operate if your hands are wet.

• 

Never touch the heater pipe or allow for the heated air to blow against your skin.

• 

Do not disassemble the product.

• 

Make sure the power switch is in the “off” position and disconnect the plug when 

the unit is not in use.

• 

When attaching the nozzle, do not press the nozzle or pull on the edge of the 

nozzle using pliers and be sure not to overtighten the screw.

• 

The power will automatically turn off when the unit exceeds a certain temperature.

Once the temperature has dropped off to a safe level, the power will automatically 

turn back on.

OPERATION
Display and Temperature Settings

• 

Press the “

+

” or “

-

” button to adjust the temperature.

• 

In short press, the set-point will change ±1°C.