International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-16-
6.
Surge Immunity
6.1
Surge immunity test
Port:
AC mains and Telephone Line
Basic Standard:
EN61000-4-5
Criteria: B
Rise Time:
1.2us
Hold Time:
50us
Temperature:
17 degree C
Humidity: 60%
Test Level:
AC Power Port: 1 kV (line to line), 2kV (line to earth)
Telephone Line: 1kV (line to ground)
Repetition Rate:
;
30 second
Angle:
;
0
°
;
90
°
;
270
°
Polarity:
;
positive
;
negative
°
Test Setup
AC power supply and
Voltage Supply to EUT
To
the
Peripherals
To AC main Supply
Non-Metallic /
Non-Conducted
Table
80
cm
Metal Full Soldered Ground Plane
Test Result
Performance of EUT complies with the given specification.
Transient-1000
EUT