International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-13-
5.
Electrical Fast transients/burst immunity
5.1
Electrical Fast transient/burst immunity test
Port: AC
mains
Basic Standard:
EN61000-4-4
Requirements: 1
KV
Criteria: B
Rise Time:
5ns
Hold Time:
50ns
Repetition Frequency: 5KHz
Temperature:
17 degree C
Humidity: 60%
Test Procedure
The EUT was setup on a nonconductive table 0.8 m above a reference ground plane.
Voltage
1 KV
Test Points
Polarity
Result
Comment
Line + N 60
sec
- N 60
sec
N
N
60
sec
- N 60
sec
N
60
sec
- N 60
sec
Line to
+
N
60 sec
Neutral -
N 60
sec
Line to
+
N
60 sec
Ground -
N
60
sec
Neutral to
+
N
60 sec
Ground -
N
60
sec
Line to Neutral
+
N
60 sec
to Ground
-
N
60 sec
Note: ’N’ means normal, the EUT function is correct during the test.