International Standards Laboratory
Report Number: ISL-01A105E
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-12-
4.
Radio-Frequency, Electromagnetic Field immunity
4.1
Radio-Frequency, Electromagnetic Field immunity test
Port: Enclosure
Basic Standard:
EN61000-4-3
Modulation
AM 1KHz 80%
Requirements: 3
V/m
Frequency range:
80 MHz~1 GHz
Step:
1% of last step frequency
Step time:
800 ms
Polarization:
Vertical and Horizontal
Criteria: A
Temperature:
22 degree C
Humidity: 41%
Test Setup
The field sensor is placed at one calibration grid point to check the intensity of the established
fields on both polarizations. EUT is adjust to have each side of EUT face coincident with the
calibration plane. A CCD camera is used to monitor the condition of EUT for the performance
judgment.
1 m
Anechoic Chamber
Non-Conducted
Table
To Amplifier output
80 cm
1.55m
To Remote Controller
Metal Full Soldered Ground Plane
To
Antenna
Test Result
Performance of EUT complies with the given specification.
EUT
Amplifier
Signal Generator