89
Chapter 4
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 74):
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
CD-ROM/Diskette drive Module
T
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
T
System board
T
LCD assembly
Содержание TRAVELMATE TravelMate 4080
Страница 8: ...Chapter 1 3 System Block Diagram ...
Страница 9: ...4 TravelMate 4070 4080 Board Layout Top View ...
Страница 56: ...51 Chapter 2 ...
Страница 61: ...Chapter 3 56 Removing the Battery 1 Unlatch the battery latch then remove the battery ...
Страница 69: ...Chapter 3 64 ...
Страница 76: ...71 Chapter 3 ...
Страница 95: ...Chapter 5 90 Top View Jumper and Connector Locations Chapter 5 ...
Страница 98: ...93 Chapter 5 ...
Страница 113: ...Chapter 6 108 ...