Chapter 4
67
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
T
System board
T
LCD assembly
Aspire 1300.book Page 67 Friday, July 26, 2002 1:41 PM
Содержание Aspire 1300
Страница 6: ...VI Aspire 1300 book Page VI Friday July 26 2002 1 41 PM ...
Страница 54: ...54 Chapter 3 Aspire 1300 book Page 54 Friday July 26 2002 1 41 PM ...
Страница 68: ...68 Chapter 4 Aspire 1300 book Page 68 Friday July 26 2002 1 41 PM ...
Страница 72: ...72 Chapter 6 Exploded Diagram THE SYSTEM LCD 14 1 ...
Страница 73: ...Chapter 6 73 LCD 15 0 FDD ASSY ...
Страница 81: ...Chapter 6 81 ...
Страница 84: ...Appendix A 84 Aspire 1300 book Page 84 Friday July 26 2002 1 41 PM ...
Страница 88: ...88 Appendix B Aspire 1300 book Page 88 Friday July 26 2002 1 41 PM ...
Страница 90: ...90 Appendix C Aspire 1300 book Page 90 Friday July 26 2002 1 41 PM ...