69
Chapter 3
Removing the Processor Air Dam (if required)
If you are using a server board that includes sockets for two processors for two processors and you install only
a single processor or remove the second processor, you must install the processor air dam in the location for
processor 2. If you install two processors, do not install the processor air dam.
For instructions on adding or replacing a processor, first remove the processor air duct and the processor air
dam, and then see your server board User Guide for instructions on processor installations and removals.
Return to these instructions to reinstall the processor air dam and processor air duct.
1.
To remove the air dam, disengage the tabls on the air dam ot pull it from under the sides of the retention
mechanism as shown.
2.
Save the air dam to replace it over the CPU2 socket in case the second processor is removed.
Installing Dimms
To install DIMMs, follow these steps:
1.
Turn off all peripheral devices connected to the server. Turn off the server.
2.
Disconnect the AC power cord from the server.
3.
Remove the server’s cover. See the documentation that accompai\nied your server chassis for
instructions on removing the server’s cover.
4.
Locate the DIMM sockets (see the figure below Installing Memory).
Содержание Altos R710
Страница 6: ...VI ...
Страница 9: ...IX Table of Contents ...
Страница 13: ...4 Chapter 1 System Block Diagram ...
Страница 14: ...Chapter 1 5 System Board Layouts Connector and Header Locations ...
Страница 23: ...14 Chapter 1 L Control Panel M Hard Drive Bays Item Description ...
Страница 72: ...63 Chapter 3 Disassembly FlowChart ...
Страница 75: ...Chapter 3 66 ...
Страница 130: ...121 Chapter 6 ...
Страница 132: ...123 Appendix A ...
Страница 146: ...137 Appendix B ...
Страница 148: ...139 Appendix C ...