![Acer Altos 19000PRO4 Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/acer/altos-19000pro4/altos-19000pro4_system-manual_8182097.webp)
System Configuration
3-53
3.6
Power Subsystem
The power subsystem consists of a power backplane, swappable
power supply modules, an optional charger board, and an optional
battery box. These components are held in place by a metal rack
enclosure.
The backplane and the rack allow installation of up to three 400-watt
power supply modules in a redundant configuration. A redundant
power configuration enables a fully-configured system to continue
running even if one power supply fails. The remaining two power
supply modules still satisfy the 800-watt system power requirement.
The charger board and the battery provide a reliable power backup in
case of a total AC power shutdown. Through the charger, the battery
continuously loads power whenever the system power is on.
The power subsystem provide a standby current and a remote on/off
feature to support cold reboot from a remote site. See Chapter 5 for
an overview of the remote diagnostic management (RDM).
Table 3-9
Power Subsystem Configuration
400W Power Module
Normal
Redundant
Configuration
1 unit
2 units or
3 units
1~2 Pentium Pro CPUs
BP-W7 (L)
7 SCSI hard disks
Full add-on card configuration
2 units
3 units
1~2 Pentium Pro CPUs
BP-W7 (L)
BP-W7 (R)
14 SCSI hard disks
Full add-on card configuration
Содержание Altos 19000PRO4
Страница 1: ...AcerAltos 19000Pro4 AcerAltos 19000Pro4 System Guide ...
Страница 8: ...viii This chapter describes how to use the AFlash BIOS Utility and the EISA Configuration Utility ...
Страница 32: ...1 14 AcerAltos 19000Pro4 System Guide ...
Страница 39: ...2 6 AcerAltos 19000Pro4 System Guide 2 2 2 Mouse Figure 2 4 Connecting a Mouse ...
Страница 40: ...Setting Up the System 2 7 2 2 3 VGA Monitor Figure 2 5 Connecting a VGA Monitor ...
Страница 64: ...3 20 AcerAltos 19000Pro4 System Guide Figure 3 21 Removing the Thermal Air Guide ...