- 13 -
Special function introduction (optional)
The following functions are made to order in accordance with the special needs of
customers:
1. Flash light function
There are corresponding interfaces for this function and provide 24v-35v flash light
voltage. Connect the flash light with DC 24v-28v, current
≤ 500mA(Fig.18). When use AC
230-240V power flash lights, please match an adapter, and wiring as required (Fig.19).
2. Pass door (SD) protection
This function ensures
that the door can‟t be opened unless the small pass door is closed.
The door panel won‟t be damaged. Connect according to Fig.17.
3. Remote lock function
4. Partial opening function
Press and hold on
„SET‟ button until the LED displays „4‟.
It‟s in remote lock function setting mode.
P
ress „UP‟ button, the LED displays „1‟, the transmitter
lock
function is available. Press „DOWN‟ button the LED
displays
„0‟, the lock function has been turned off.
Press „SET‟ to confirm.
You have to press lock button on remote a few seconds
later after the door was fully closed, then you can open the
door again by remote.
Press and hold on
„SET‟ button until the LED displays figure
„5‟. It‟s in partial opening function setting mode.
Press
„UP‟ or „DOWN‟ button, the LED will display figure „0‟
to
„9‟ automatically.
When LED displays
‟0‟, the partial opening function is
invalid;
When displays
„1‟, the door will stop at 30cm above ground;
When displays
„2‟, the door will stop at 60cm above ground,
and so forth.
When LED displays
‟9‟, the door will stop at 270cm above
ground.
The function defaults to invalid when the stated range is
over than the door‟s limited opening range.
Press
„SET‟ button again to confirm.
Lock button
Lock button
Lock button
Partial
opening
Partial
opening
Partial
opening
Содержание RAPTOR
Страница 16: ...14 Wiring guide Fig 15 Fig 16 Fig 17 Fig 19 Fig 18...
Страница 20: ...18 1 0 0 220105...