Accutrol IAQ-Tek Скачать руководство пользователя страница 2

W

ARRANTY 

S

TATEMENT

 

 
 
 

Accutrol  LLC,  having  its  principal  place  of  business  at  21 Commerce Dr.  Danbury, CT  USA  ("Manufacturer")  warrants 
its IAQ-TEK Outdoor Airflow Transmitter product (the "Products") as follows: 

 

1.  Limited Warranty. 
Manufacturer warrants that the Products sold hereunder will be free from defects in material and workmanship for a 
period of thirty-six (36) months from the date of purchase.   If the Products do not conform  to this Limited Warranty 
during  the  warranty  period  (as  herein  above  specified),  Buyer  shall  notify  Manufacturer  in  writing  of  the  claimed 
defects and demonstrate to Manufacturer

s satisfaction that said defects are covered by this Limited Warranty.  If the 

defects  are  properly  reported  to  Manufacturer  within  the  warranty  period,  and  the  defects  are  of  such  type  and 
nature as to be covered by this warranty, Manufacturer shall, at its own expense, furnish, replacement Products or, at 
Manufacturer's  option,  replacement  parts  or  services  for  the  defective  Products.    Shipping  and  installation  of  the 
replacement Products or replacement parts shall be at Buyer's expense. 

 

2.  Other Limits. 
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE 
IMPLIED  WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE.    Manufacturer  does  not 
warrant  against  damages  or  defects  arising  out  of  improper  or  abnormal  use  or  handling  of  the  Products;  against 
defects  or  damages  arising  from  improper  installation  (where  installation  is  by  persons  other  than  Manufacturer), 
against  defects  in  products  or  components  not  manufactured  by  Manufacturer,  or  against  damages  resulting  from 
such non-Manufacturer made products or components.  Manufacturer passes on to Buyer the warranty it received (if 
any) from  the maker  thereof  of such non-Manufacturer made products or  components.   This warranty also does not 
apply  to  Products  upon  which  repairs  have  been  affected  or  attempted  by  persons  other  than  Manufacturer  or 
pursuant to written authorization by Manufacturer.  This warranty also does not apply to any product provided by the 
Buyer and mounted by the Manufacturer to Products. 

 

3.  Exclusive Obligation. 
THIS WARRANTY IS EXCLUSIVE.    The  sole  and  exclusive  obligation  of  Manufacturer  shall  be  to repair  or replace  the 
defective  Products  in  the  manner  and  for  the  period  provided  above.    Manufacturer  shall  not  have  any  other 
obligation  with  respect  to  the  Products  or  any  part  thereof,  whether  based  on  contract,  tort,  strict  liability  or 
otherwise.   Under  no  circumstances,  whether  based  on  this  Limited  Warranty  or  otherwise,  shall  Manufacturer  be 
liable for incidental, special, or consequential damages. 

 

4.  Other Statements. 
Manufacturer's  employees  or  representatives'  ORAL  OR  OTHER  WRITTEN  STATEMENTS  DO  NOT  CONSTITUTE 
WARRANTIES, shall not be relied upon by Buyer, and are not a part of the contract for sale or this limited warranty. 

 

5.  Entire Obligation. 
This Limited Warranty states the entire obligation of Manufacturer with respect to the Products.   If any part of this 
Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect. 

Содержание IAQ-Tek

Страница 1: ...IAQ Tek Outdoor Airflow Transmitter Installation Operation Maintenance Manual Released Sept 2019 Accutrol LLC 21 Commerce Dr Danbury CT 06810 Tel 203 445 9991...

Страница 2: ...tallation where installation is by persons other than Manufacturer against defects in products or components not manufactured by Manufacturer or against damages resulting from such non Manufacturer ma...

Страница 3: ...lation 4 Step 4 Monitor Installation 5 Step 5 Tubing 6 Step 6 Wiring 7 Step 7 Power Up 8 Basic Display and Keypad Operation 9 Password Operation 9 Verifying Functionality Using Diagnostic Alarms 11 Us...

Страница 4: ...e Probe Kit Shown Below PN 2001ASM00320 Probe 10 Tubing End Brackets Vertical Brackets For two probe configuration quantity of each item in the kit doubles and two T Fittings are included For three pr...

Страница 5: ...upper end bracket to the upper mounting surface using 2 lock washers and 2 sheet metal screws provided Make sure the back of the Probe is at least six inches from the fully open damper Step 2b Attach...

Страница 6: ...nt the transducer using 4 screws suitable for the 3 16 holes provided in the mounting bracket This mounting hardware is not included in the kit High High High High Low Low Low Low Step 4 Monitor Insta...

Страница 7: ...IGH PRESSURE SIDE HIGH PRESSURE SIDE LOW PRESSURE S Note The tubing must run continuous directly from the probe to the transducer with no kinks pockets or loops Multiple Probe Configuration Step 5d Co...

Страница 8: ...the cable end through the strain relief fitting and terminate the transducer wires to the monitor 9 pin terminal block per Figure 3 Be sure to secure each screw after landing wire in the proper locati...

Страница 9: ...ate terminal blocks per Figure 5 Be sure to secure each screw after landing wire in the proper location Secure the strain relief fitting nut ALARM normally Energized Alarm to BAS Fan Run Contact NO OA...

Страница 10: ...through the various selections Will index the selection of a particular item ENTER Will change the value to the one indexed All entries of ENTER shall be followed by a message which asks the user to c...

Страница 11: ...he building operators that the intake volume has fallen below the minimum acceptable level The basis of the alarm shall be the result of the Balancer Adjusted CFM BCFM The Low Flow Alarm set point is...

Страница 12: ...rm flag will be initiated immediately and without delay Loss of Enclosure Heater Should the enclosure temperature fall to eleven degrees below the enclosure temperature set point an Enclosure Heater A...

Страница 13: ...mnt Wizard Steps 1 through 8 will guide you through the IAQ TEK Set Up using the Wizards Note The Pressure Transducer has an internal heating element which must be stabilized at set point before proce...

Страница 14: ...6 Once you have completed the procedure the display should now read BALANCER SETUP Monitor CFM Balancer CFM Error If the Error is less than 25 hit the ENTER key You will then be asked to Use Balancer...

Страница 15: ...type of differential pressure generating device being used Following is a list a standard Tek Air products and their respective SFC Generic Pitot 1 00 TFP 5000 or 6000 0 754 TPS 6000 0 624 IAQ TEK Pr...

Страница 16: ...rved by the Balancer Enter the BAF as a percentage of monitor reading For example if the monitor indicates the flow 1000 CFM and the Balancer indicates the flow is 900 CFM the BAF is 1000 900 90 Facto...

Страница 17: ...user can view the status of the digital input contact as OPEN or CLOSED Test Analog Output 1 When indexed this function will cause the 4 20mA Output CFM OUT to step from 4 ma to 12 mA to 20 mA and rep...

Страница 18: ...ting 40 to 120 F Storage 40 to 150 F Air Velocity Capabilities Discharge of intake louver 75 to 750 FPM Free Air before damper 100 to 1000 FPM Probe Material PVC ABS Fire Rating UL 94 V0 and UL 94 5VB...

Страница 19: ...wer Supply Voltage 24 VAC limits 19 31 VAC Power 25 VA Digital Input for Fan Status Interlock Type Dry Contact Analog Outputs Type Powered and Isolated 4 20mA Scaling CFM user set Temperature 30 to 12...

Страница 20: ...lenum Rain Hood OA Damper OA Damper Air Handler Mixing Plenum Air Handler Mixing Plenum Cap Type Rain Hood Intake louver OA Damper R e t u r n Before d Modification a m p e r OA Damper louver R e t OA...

Страница 21: ...A 2 r louver O A d a m p e r R e t d a m p e r O A d a m p e louver McQuay Type Intake O l A o d u a v m e p r e r Standard Air Intake Rain Hood DPR Rain Hood Air Handler Mixing Plenum Standard Rain H...