Storage

1.  When not in use, the PachPen Pachymeter and all accessories should be 

placed in the storage case.

2.  If the PachPen Pachymeter is not to be used for an extended period of time, 

remove the battery from the device.

Troubleshooting

Refer to Table 4.1 below for information in identifying and correcting problems that 
can occur with the PachPen.

Table 4.1 - PachPen Troubleshooting Information

Symptom

Probable Cause

Correction

“LOW BATT” 

Displayed

Battery is low

Replace battery (see chapter 3)

Multiple variable 

readings

Improper technique

Review measurement technique

Battery is low

Replace battery (see chapter 3)

Mechanical or electronic 
damage

Arrange for repair through 
Accutome Technical Service Group 
(see chapter 6)

No beep and/or 

no display upon 

activation

Action Control Button not 
held down long enough

Hold down Action Control Button 
longer

Incorrect battery 
installation

Check battery installation

Battery is low

Replace battery (see chapter 3)

Mechanical or electronic 
damage

Arrange for repair through 
Accutome Technical Service Group 
(see chapter 6)

No Readings

Improper technique

Review measurement technique

Incorrect battery 
installation

Check battery installation

Battery is low

Replace battery (see chapter 3)

Mechanical or electronic 
damage

Arrange for repair through 
Accutome Technical Service Group 
(see chapter 6)

Содержание PachPen

Страница 1: ...PachPen User s Guide PachPen Handheld Pachymeter 24 5102 Rev H...

Страница 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient...

Страница 3: ...the Probes with Alcohol 5 High Level Disinfection of the Probe 5 Electrical Hazard and Safety 5 Avoiding Equipment Damage 5 Avoiding Electromagnetic and Other Interference 6 Chapter 3 Getting Started...

Страница 4: ...torage 14 Troubleshooting 14 Chapter 5 Specifications 15 Overview 15 Physical Specifications 15 Environmental Specifications 15 Measurement Accuracy 16 Operating Modes 16 Acoustic Output 17 Chapter 6...

Страница 5: ...Correction Values 11 Table 4 1 PachPen Troubleshooting Information 14 Table 5 1 PachPen Physical Specifications 15 Table 5 2 Environmental Specifications 15 Table 5 3 Measurement Accuracy 16 Table 5...

Страница 6: ...accomplish even the complex simply The PachPen provides the following general features Multi segment high resolution LCD screen with control buttons to provide an intuitive user interface Long lastin...

Страница 7: ...guide for technicians optometrists and ophthalmologists who are experienced in ultrasonic biometric techniques This manual is organized as follows Chapter 2 Safety Summarizes safety precautions warni...

Страница 8: ...posal Requirements Disposal of the product within the EU The PachPen contains electronic components At the end of its useful life it must be properly disposed of in compliance with local regulations E...

Страница 9: ...ed between patients to prevent patient to patient transfer of infection It is the user s responsibility to ensure that the relevant standards are maintained and that the products and procedures are ef...

Страница 10: ...ome probes Note Be sure to follow the disinfectant manufacturer s written protocol when using any antibacterial solution including high level disinfectants Electrical Hazard and Safety The PachPen is...

Страница 11: ...EMATURE FAILURE OF THE DEVICE Avoiding Electromagnetic and Other Interference Do not use a cellular telephone or other device not compliant with EMC Class B requirements as its signals may cause the e...

Страница 12: ...a lanyard should be included inside the case The additional openings in the case foam are for storing alcohol prep pads and a bottle of ophthalmic anesthetic if you wish 3 Visually inspect the PachPen...

Страница 13: ...by unscrewing the captive battery door screw The battery door is hinged to the bottom of the handle and should not be removed from the product 2 Insert the XENO model XLP 050F lithium battery or an e...

Страница 14: ...consists of the following steps 1 Power on the PachPen instrument 2 Take up to nine measurements 3 Enter the measured IOP and calculate the corrected IOP for each eye 4 Record the data in the Patient...

Страница 15: ...e expires Notes 1 The PachPen can take up to nine measurements and provide the average of those measurements This average is the number used when calculating the True IntraOccular Pressure TIOP 2 The...

Страница 16: ...s Figure 3 7 True IOP Screen Table 3 1 IOP Correction Values Corneal Thickness micrometers Correction Values mmHg 405 7 425 6 445 5 465 4 485 3 505 2 525 1 545 0 565 1 585 2 605 3 625 4 645 5 665 6 68...

Страница 17: ...alcohol or in an ultrasonic cleaner and allowing it to air dry Do not drop the device Avoid any shock or excessive vibration as this may damage the unit Do not immerse the device in any fluid This wil...

Страница 18: ...s once the decomposition or neutralization process has terminated Disposal in the United States Lithium batteries are neither specifically listed nor exempted from the federal Environmental Protection...

Страница 19: ...ptom Probable Cause Correction LOW BATT Displayed Battery is low Replace battery see chapter 3 Multiple variable readings Improper technique Review measurement technique Battery is low Replace battery...

Страница 20: ...ght 85 g 3 oz Display Type Multi Segment Monochrome Liquid Crystal Display LCD Size 28 6 mm 1 13 Diagonal Viewable Area Probe Frequency 10 5 MHz Composite Sample Frequency 65 MHz Safety Meets EN 60601...

Страница 21: ...Modes The following table summarizes the mode application possibilities for each system transducer combination Table 5 4 Operating Modes Clinical Application A B M PWD CWD CD Combined specify Other s...

Страница 22: ...e A Mode Application s Ophthalmic Table 5 5 Acoustic Output Reporting Table for Track 1 Non Autoscanning Mode Acoustic Output MI ISPTA 3 mW cm2 ISPPA 3 W cm2 Global Maximum Value 0 154 0 0145 8 53 Ass...

Страница 23: ...nnected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 N A Voltage fluctuations flicker emissions IEC 61000 3 3 Comp...

Страница 24: ...etermined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Ra...

Страница 25: ...sponsibility of the customer Alteration repair or modification of any product that is performed by persons not authorized by Accutome Inc will immediately void the warranty Product Returns Follow the...

Страница 26: ...or Merchandise held longer than 60 days Replacement Parts Table 6 1 below lists items that are available from Accutome Inc or from your local sales representative Please be sure to use the Accutome pa...

Страница 27: ...US and Canada 800 979 2020 International 610 889 0200 European Office 31 0 485 350300 Info accutome com www accutome com...

Отзывы: