P/N 800-1090-104 Rev L102012
Page 10 of 44
Corner-To-Corner Measuring:
Place the ProPanel jaws over opposite corners. Gently "wiggle" the ProPanel
while applying light closing pressure to seat the corners. Change to
Incremental mode. (Press the
DATUM
key to zero the display if necessary.)
Measure the second diagonal. The difference in diagonal lengths will be
shown on the Readout.
Hole-To-Hole Measuring
Install the two “
full cone
” attachments to the underside of the measuring jaws.
Push the F1 key until the LCD displays a “
2
”. This indicates the value
programmed for offset addition 2 (
), will be
automatically applied to any measurement.
Place the cones into the holes to be measured. Be sure the cones are fully
seated in the holes. Do not press down on the rail of the ProPanel, as this
may affect accuracy. The Hole-to-Hole distance is read diectly on the Display.
Edge-To-Hole Measuring
Install one full cone attachment and one half cone attachment. Push the F1
key until the LCD dis
plays a “
3
”. This indicates the value programmed for
offset addition 3 (
), will be automatically applied
to any measurement.
Place the full cone in the hole and the half cone against the edge of the panel.
Keeping the ProPanel rail equidistant from the part (by adjusting the half
cone's position up or down) will assure the highest accuracy possible.
The Edge-to-Hole distance is read diectly on the Display.
Refer to Section 3: