Frequently Asked Questions 

What F/W (Firmware) version do I have? 

 

The readout will display 

d 2.xxx

 on power up.   

This is the firmware version of your readout . 

 
The readings are “backwards”? 

 

You  can  change  reading  direction  of  the  Digi-Fence  by  changing  the  value  of 

Programming Parameter Pr 2.  

 

The keys don’t seem to do what they are supposed to do. 

Timing, which is how long a key is depressed, and the combination of the keys 
pressed is important.  This manual uses the term ‘”

momentarily

” to describe a 

key press of shorter than 1 second. Whereas the term 

“press and hold

” is used 

to describe a key press of longer than 1.5 seconds. As an example; when using 
a PC keyboard to type a capital letter you would “

press and hold

” the SHIFT 

key and “

momentarily

 depress the LETTER key.  In addition most of the key 

functions

” are executed on RELEASE, not press.  This is important since some 

of the same keys execute different functions based on how long they are 
pressed and when they are released.  These key operations, once tried will 
quickly become intuitive.  

 

What does 

no Enc

 

mean? 

 

If the encoder cable is unplugged from the readout , 

no Enc

 

will appear on the 

display.    To  clear:  Be  sure  the  encoder  is  on  the  scale  and  plugged  into  the 
readout. 

 

What does 

b FAIL

 mean? 

 

When  the  readout  displays  this  message  it  means  the  battery  voltage  has 
dropped  to  a  level  where  reliable  operation  is  no  longer  possible.    Install  new 
batteries to clear this message. 

 

What does 

P FAIL

 mean? 

 

When  the  readout  displays  this  message  it  means  the  battery  voltage  has 
dropped  to  a  level  where  reliable  programming  is  not  possible.    Install  new 
batteries to clear this message. 

Содержание DigiStop-4

Страница 1: ...Digi Stop Installation Operation...

Страница 2: ...es of merchantability or fitness for a particular purpose except as expressly provided in this agreement Accurate Technology Inc shall not be liable for any special incidental or consequential damages...

Страница 3: ...l Stop Assembly 7 Calibration 8 Changing the Battery 8 The LCD Display 9 Maintenance 9 SECTION 3 OPERATION 10 Readout Keys 10 Key Timing 10 On Off 10 Units Key 10 DATUM and 11 Reverse the Measurement...

Страница 4: ...ck fence is desired It has been designed using high quality extruded and machined parts to provide the best accuracy and repeatability DigiStop is the consumer version of Accurate Technology s commerc...

Страница 5: ...nch 1mm or 01inch 01mm or 001inch 01mm or 1 16inch 1 32inch 1 64 inch Repeatability 001in or 01mm Display Range 999 999 in 399 63 64 in 9999 99 mm Operating Temp 32 to 120 F 0 to 51 C Max Slew Rate 40...

Страница 6: ...kages depending on the model The first contains the Fence extrusion with the Scale attached The second package if necessary contains the Digital Stop and installation hardware Pictured below are parts...

Страница 7: ...end first back into place capturing the bolt heads in the bottom T slot of the Fence Assembly After the Fence is in place and aligned to the saw tighten all nuts Install Stop Assembly 1 Carefully slid...

Страница 8: ...d is shown The longer the key is held down the faster the readout will scroll This adjustment should be made in a decimal inches or mm mode for the best accuracy 5 When the correct reading is reached...

Страница 9: ...st display the current firmware version and RESET ALL PROGRAMMING PARAMETERS TO FACTORY DEFAULTS Maintenance The fence extrusion should be cleaned of debris periodically Do not use any liquid lubrican...

Страница 10: ...l quickly become intuitive On Off Momentarily pressing the ON OFF key will cause the readout to turn on or off The Firmware Version of the readout is displayed on power up when the ON OFF key is used...

Страница 11: ...er Pr1 default is zero 0 00 Momentarily depressing the key increments the current reading by one unit fractions decimal or mm depending on the current mode selected by the UNITS key of measurement Mom...

Страница 12: ...ut Programming Programming Parameter Pr3 Readout Resolution The Digital readout can be configured to display measurements in any of three different resolutions 1 Low the resolution is 1in or 1mm 2 Nor...

Страница 13: ...en power is first applied This is indicated by the ABS symbol in the upper left corner of the display While in the ABS mode all fence positions are related to the current ABS or absolute system refere...

Страница 14: ...urable jumpers consisting of three pins and a shorting block or jumper The center of these three pins is Common One end pin is labeled A and the other end pin is labeled B JP1 FACTORY USE ONLY JP2 Pro...

Страница 15: ...Programming Parameter number then the currently programmed value Moving down parameter list Press and hold the ON OFF key and momentarily press the UNITS key to move backward through the Programming...

Страница 16: ...direction of travel positive vs negative when the encoder is moved Default 0 Pr 3 Key Lockout 0 or 1 This parameter controls the operation of the and DATUM keys If enabled set to 1 these keys will not...

Страница 17: ...alue 15 minutes Pr13 Linear Compensation 0 00001 to 9 99999 This parameter invokes a linear multiplier correction in the Readout that is applied to the actual measurement prior to any offsets This adj...

Страница 18: ...u would press and hold the SHIFT key and momentarily depress the LETTER key In addition most of the key functions are executed on RELEASE not press This is important since some of the same keys execut...

Страница 19: ...Accurate Technology Digi Stop Page 19 of 20...

Страница 20: ...ADE PRODUCT Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 828 654 7920 Please register your product at http www proscale com registration htm This manual is available online at...

Отзывы: