background image

 

Accurate Technology Digi-Stop 

Page 15 of 20 

 

Readout Programming  

Several  functions  of  the  Digi-Stop

 

Readout  are  user  programmable.    The 

following  describes  what  features  and  functions  are  available  and  how  to 
change the factory defaults to customize your Digi-Fence system..  
Review KEY TIMING described earlier before proceeding. 

 

To enter Programming Mode:  
 

1.  Press and hold the

 

UNITS

 key then momentarily press the 

DATUM

 key. 

2.  The LCD will briefly display: 

PG  on

 (Programming On),  then  

Pr  1

, (indicating Programming Parameter #1)  

3.  Release the 

UNITS

 key 

4.  The value stored in 

Pr1 

is displayed. 

 

 
 
 
 
 

 
 

 

Once in the Programming Mode:  
 

Moving up parameter list - Momentarily press the 

UNITS

 

key to advance through 

the  Programming  Parameter  list,  first  displaying  the  Programming  Parameter 
number then the currently programmed value. 
 
Moving down parameter list  - Press and hold the 

ON

/

OFF

 key and momentarily 

press the 

UNITS

 

key to move backward through the Programming list. 

 
Increase parameter value - Momentarily press the 

PLUS

 

(+)

 key while displaying 

a Programming Parameter Value to increase the setting. 

Decrease parameter value - Momentarily press the 

MINUS

 

(-)

 key while 

displaying a Programming Parameter Value to decrease the setting. 

Reset parameter value to default setting - Momentarily press the 

DATUM

  key 

while displaying a Programming Parameter Value to reset the parameter to the 
factory default value. 

Exit programming mode - Press and hold the

 

UNITS

 key.  Momentarily depress 

the 

DATUM

 key.  The LCD will briefly display: 

PG  oFF

 (Programming Off),   

then return to normal operation.  

NOTE

: The system will automatically exit 

programming mode after 60 seconds if no key activity is detected. 

Momentarily press 

Press & Hold  

Содержание DigiStop-4

Страница 1: ...Digi Stop Installation Operation...

Страница 2: ...es of merchantability or fitness for a particular purpose except as expressly provided in this agreement Accurate Technology Inc shall not be liable for any special incidental or consequential damages...

Страница 3: ...l Stop Assembly 7 Calibration 8 Changing the Battery 8 The LCD Display 9 Maintenance 9 SECTION 3 OPERATION 10 Readout Keys 10 Key Timing 10 On Off 10 Units Key 10 DATUM and 11 Reverse the Measurement...

Страница 4: ...ck fence is desired It has been designed using high quality extruded and machined parts to provide the best accuracy and repeatability DigiStop is the consumer version of Accurate Technology s commerc...

Страница 5: ...nch 1mm or 01inch 01mm or 001inch 01mm or 1 16inch 1 32inch 1 64 inch Repeatability 001in or 01mm Display Range 999 999 in 399 63 64 in 9999 99 mm Operating Temp 32 to 120 F 0 to 51 C Max Slew Rate 40...

Страница 6: ...kages depending on the model The first contains the Fence extrusion with the Scale attached The second package if necessary contains the Digital Stop and installation hardware Pictured below are parts...

Страница 7: ...end first back into place capturing the bolt heads in the bottom T slot of the Fence Assembly After the Fence is in place and aligned to the saw tighten all nuts Install Stop Assembly 1 Carefully slid...

Страница 8: ...d is shown The longer the key is held down the faster the readout will scroll This adjustment should be made in a decimal inches or mm mode for the best accuracy 5 When the correct reading is reached...

Страница 9: ...st display the current firmware version and RESET ALL PROGRAMMING PARAMETERS TO FACTORY DEFAULTS Maintenance The fence extrusion should be cleaned of debris periodically Do not use any liquid lubrican...

Страница 10: ...l quickly become intuitive On Off Momentarily pressing the ON OFF key will cause the readout to turn on or off The Firmware Version of the readout is displayed on power up when the ON OFF key is used...

Страница 11: ...er Pr1 default is zero 0 00 Momentarily depressing the key increments the current reading by one unit fractions decimal or mm depending on the current mode selected by the UNITS key of measurement Mom...

Страница 12: ...ut Programming Programming Parameter Pr3 Readout Resolution The Digital readout can be configured to display measurements in any of three different resolutions 1 Low the resolution is 1in or 1mm 2 Nor...

Страница 13: ...en power is first applied This is indicated by the ABS symbol in the upper left corner of the display While in the ABS mode all fence positions are related to the current ABS or absolute system refere...

Страница 14: ...urable jumpers consisting of three pins and a shorting block or jumper The center of these three pins is Common One end pin is labeled A and the other end pin is labeled B JP1 FACTORY USE ONLY JP2 Pro...

Страница 15: ...Programming Parameter number then the currently programmed value Moving down parameter list Press and hold the ON OFF key and momentarily press the UNITS key to move backward through the Programming...

Страница 16: ...direction of travel positive vs negative when the encoder is moved Default 0 Pr 3 Key Lockout 0 or 1 This parameter controls the operation of the and DATUM keys If enabled set to 1 these keys will not...

Страница 17: ...alue 15 minutes Pr13 Linear Compensation 0 00001 to 9 99999 This parameter invokes a linear multiplier correction in the Readout that is applied to the actual measurement prior to any offsets This adj...

Страница 18: ...u would press and hold the SHIFT key and momentarily depress the LETTER key In addition most of the key functions are executed on RELEASE not press This is important since some of the same keys execut...

Страница 19: ...Accurate Technology Digi Stop Page 19 of 20...

Страница 20: ...ADE PRODUCT Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 828 654 7920 Please register your product at http www proscale com registration htm This manual is available online at...

Отзывы: