1. Safety 

1.1 Instructions for safe operations 

0

 

Check the main unit and all accessories periodically to make sure that there is no visible 

damage that may affect patient’s safety and monitoring performance. It is recommended that 

the device should be inspected once a week at least. Please stop using the monitor when there is 

obvious damage. 

0

 

Necessary maintenance must be performed by qualified service engineers ONLY. Users are not 

permitted to maintain it by themselves. 

0

 

The oximeter cannot be used together with devices not specified in User’s Manual. Please use 

the devices recommend by Manufacturer. 

1.2 Warnings 

0

 

Explosive hazard—DO NOT use the oximeter in environment with inflammable gas such as 

some ignitable anesthetic agents. 

0

 

DO NOT use the oximeter while the testee is under measurement of MRI and CT. 

0

 

Be cautious of the hanging rope, please do not break

 

the hanging rope during usage to avoid 

device damage. Please don’t use hanging rope if allergic to hanging rope. 

0

 

Please don’t use this product if allergic to rubber cushion. 

0

 

Please dispose the device, accessory and packing (including plastic bag, foam and carton) 

according to local law. 

1.3 Attentions 

 

Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high 

temperature and moisture. 

 

If the oximeter gets wet, please stop using.   

 

When it is carried from cold environment to warm and humid environment, please not use it 

immediately. 

 

DO NOT operate keys on front panel with sharp materials. 

 

High temperature or high pressure steam disinfection of the oximeter is not permitted. Refer to 

User’s Manual for instructions of cleaning and disinfection. 

 

Do not have the oximeter immerged in liquid. When it needs cleaning, please wipe its surface 

with disinfect solution by soft material. Do not spray any liquid on the device directly. 

 

When cleaning the device with water, the temperature should be less than 60

2.

 

Overview 

The pulse oxygen saturation is the percentage of HbO

2

 in the total Hb in the blood, so-called the O

 

1

Содержание CMS-50D

Страница 1: ...l includes the Fingertip Pulse Oximeter s features and requirements main structure functions specifications correct methods for transportation installation usage operation repair maintenance and stora...

Страница 2: ...ce does not cover such faults This product is medical device and can be used repeatedly Its using life is 3 years WARNING 0 Uncomfortable or painful feeling may appear if using the device ceaselessly...

Страница 3: ...CAUTION 3 3 1 PRINCIPLE OF MEASUREMENT 3 3 2 THE ATTENTION OF OPERATION 3 3 3 CLINICAL RESTRICTIONS 4 4 TECHNICAL SPECIFICATIONS 4 5 ACCESSORIES 5 6 INSTALLATION 5 6 1 VIEW OF THE FRONT PANEL 5 6 2 M...

Страница 4: ...avoid device damage Please don t use hanging rope if allergic to hanging rope 0 Please don t use this product if allergic to rubber cushion 0 Please dispose the device accessory and packing including...

Страница 5: ...in the range from 70 to 100 2 1 Features A The device can accurately measure SpO2 B The device will power off automatically if no signal is detected within 5 seconds C Two AAA size batteries are requi...

Страница 6: ...unctional O2Hb saturation O2Hb RHb O2Hb x 100 Present SpO2 oximeter transmits light of two wavelengths only red light wavelength 660 nm and infrared wavelength 940nm to differentiate HbO2 from HbR One...

Страница 7: ...t body temperature major bleeding or use of vascular contracting drug the SpO2 waveform PLETH will decrease In this case the measurement will be more sensitive to interference B For those with a subst...

Страница 8: ...se saturation is at 0 4 Accuracy of SpO2 4 Accuracy of Pulse rate 2bpm or 2 select larger G Resistance to surrounding light The difference between the value measured in the condition of man made light...

Страница 9: ...gure 3 And insert the two AAA size batteries properly in the right direction according to the and symbol 2 Replace the cover Please be cautious when you insert the batteries for improper insertion may...

Страница 10: ...clip as shown in Figure 5 Figure5 Put finger in position C Let the patient s finger put into the rubber cushions of the clip make sure the finger is in the right position and then clip the finger a Pr...

Страница 11: ...ong time 4 The best storage environment of the device is 20 C to 55 C ambient temperature and not higher than 95 relative humidity Please maintain properly for ensuring the device can be used normally...

Страница 12: ...e center The display is off suddenly 1 The device will power off automatically if no signal is detected within 5 seconds 2 The batteries are almost drained 1 Normal 2 Change batteries 11 Function Spec...

Страница 13: ...stronger pulse Battery Requirement 1 5V AAA size alkaline batteries 2 Battery useful life The two batteries can work continually 30 hours Dimensions and Weight Dimensions 57 L 31 W 32 H mm Weight Abou...

Страница 14: ...Alarm inhibit 11...

Отзывы: