Instructions to User 

 

Dear Users, thank you very much for purchasing Fingertip Pulse Oximeter. Please read the 

following two pages very carefully before using this equipment.   

Please read these instructions carefully before using this equipment. These instructions describing 

the operating procedures should be followed strictly. Failure to follow these instructions can cause 

measuring abnormality, equipment damage and personal injury. The manufacturer is NOT 

responsible for the safety, reliability and performance issues and any monitoring abnormality, 

personal injury and equipment damage due to user’s negligence of the operation instructions. The 

manufacturer’s warranty service does not cover such faults.                                                                                                

This product is medical device, and can be used repeatedly. Its using life is 3 years.

 

 

 

 

WARNING: 

0

 

Uncomfortable or painful feeling may appear if using the device ceaselessly, especially 

for the microcirculation barrier patients. It is recommended that the sensor should not 

be applied to the same finger for over 2 hours. 

0

 

For the special patients, there should be a more prudent inspecting in the placing 

process. The device can not be clipped on the edema and tender tissue. 

0

 

The light (the infrared is invisible) emitted from the device is harmful to the eyes, so the 

user and the maintenance man should not stare at the light. 

0

 

Testee can not use enamel or other makeup. 

0

 

Testee’s fingernail can not be too long. 

0

 

Please refer to the correlative literature about the clinical restrictions and caution. 

0

 

This device is not intended for treatment. 

 

 

 

 

 

 

II

Содержание CMS-50D

Страница 1: ...l includes the Fingertip Pulse Oximeter s features and requirements main structure functions specifications correct methods for transportation installation usage operation repair maintenance and stora...

Страница 2: ...ce does not cover such faults This product is medical device and can be used repeatedly Its using life is 3 years WARNING 0 Uncomfortable or painful feeling may appear if using the device ceaselessly...

Страница 3: ...CAUTION 3 3 1 PRINCIPLE OF MEASUREMENT 3 3 2 THE ATTENTION OF OPERATION 3 3 3 CLINICAL RESTRICTIONS 4 4 TECHNICAL SPECIFICATIONS 4 5 ACCESSORIES 5 6 INSTALLATION 5 6 1 VIEW OF THE FRONT PANEL 5 6 2 M...

Страница 4: ...avoid device damage Please don t use hanging rope if allergic to hanging rope 0 Please don t use this product if allergic to rubber cushion 0 Please dispose the device accessory and packing including...

Страница 5: ...in the range from 70 to 100 2 1 Features A The device can accurately measure SpO2 B The device will power off automatically if no signal is detected within 5 seconds C Two AAA size batteries are requi...

Страница 6: ...unctional O2Hb saturation O2Hb RHb O2Hb x 100 Present SpO2 oximeter transmits light of two wavelengths only red light wavelength 660 nm and infrared wavelength 940nm to differentiate HbO2 from HbR One...

Страница 7: ...t body temperature major bleeding or use of vascular contracting drug the SpO2 waveform PLETH will decrease In this case the measurement will be more sensitive to interference B For those with a subst...

Страница 8: ...se saturation is at 0 4 Accuracy of SpO2 4 Accuracy of Pulse rate 2bpm or 2 select larger G Resistance to surrounding light The difference between the value measured in the condition of man made light...

Страница 9: ...gure 3 And insert the two AAA size batteries properly in the right direction according to the and symbol 2 Replace the cover Please be cautious when you insert the batteries for improper insertion may...

Страница 10: ...clip as shown in Figure 5 Figure5 Put finger in position C Let the patient s finger put into the rubber cushions of the clip make sure the finger is in the right position and then clip the finger a Pr...

Страница 11: ...ong time 4 The best storage environment of the device is 20 C to 55 C ambient temperature and not higher than 95 relative humidity Please maintain properly for ensuring the device can be used normally...

Страница 12: ...e center The display is off suddenly 1 The device will power off automatically if no signal is detected within 5 seconds 2 The batteries are almost drained 1 Normal 2 Change batteries 11 Function Spec...

Страница 13: ...stronger pulse Battery Requirement 1 5V AAA size alkaline batteries 2 Battery useful life The two batteries can work continually 30 hours Dimensions and Weight Dimensions 57 L 31 W 32 H mm Weight Abou...

Страница 14: ...Alarm inhibit 11...